Commands
Field
Field
Name
1
LOG
(ASCII)
header
2
port
3
message
4
trigger
5
period
6
offset
7
hold
SMART-AG User Manual Rev 2
ASCII
Value
-
See Table 12, Detailed
Serial Port Identifiers on
Page 62
Any valid message name,
with an optional A or B
suffix.
ONNEW
ONCHANGED
ONTIME
ONNEXT
ONCE
ONMARK
Any positive double value
larger than the receiver's
minimum raw
measurement period
Any positive double value
smaller than the period.
NOHOLD
HOLD
Description
This field contains the command name or the
message header depending on whether the
command is abbreviated ASCII or ASCII
respectively.
Output port
(default = THISPORT)
Message name of log to output
Output when the message is updated (not
necessarily changed)
Output when the message is changed
Output on a time interval
Output only the next message
Output only the current message. (default)
Output when a pulse is detected on the mark 1
input, MK1I
Log period (for ONTIME trigger) in seconds
(default = 0)
Offset for period (ONTIME trigger) in seconds. If
you wished to log data at 1 second after every
minute you would set the period to 60 and the
offset to 1 (default = 0)
Allow log to be removed by the UNLOGALL
command (default)
Prevent log from being removed by the
UNLOGALL command
Appendix B
Field
Type
-
Enum
Char [ ]
Enum
Double
Double
Enum
61