Stove data table in accordance with EN 13240 testing.
Stove
Nominal
Smoke
fluegas
type
stub
Scan-Line
tempera-
series
ture c°
mm
40
257
ø150
50
257
ø150
The nominal output is the output to which the stove has been tested.
The test was carried out with the secondary air 70% open.
OPERATIONAL PROBLEMS
The chimney must be swept at least
once a year, we recommend the use
of a NACS (national association of
chimney sweeps) registered chim-
ney sweep. In the event of smoke or
malodorous fumes being produced,
you must first check to see whether
the chimney is blocked. The chimney
must, of course, always provide the
minimum draught necessary to ensure
that it is possible to regulate the fire.
Please note, however, that chimney
draft is dependent on the weather
conditions. In high winds, the draft
can become so powerful that it may
be necessary to fit a damper in the
MAINTENANCE
The surface of the stove has been trea-
ted with heat-resistant paint.
The stove should be cleaned with a
damp cloth. Any damage to the sur-
face in the form of chips or scratches
can be repaired using touch-up paint,
which is available in spray cans.
6
Fuel
Draught
Nominal
volume
min
output
tested
kg
mbar
kW
1.6
0.12
5
1.6
0.12
5
Heat
Distance to flammable
output
materials in mm
behind
at the
kW
the stove
sides
5
150
400
5
150
400
flue gas pipe to regulate the draft.
When cleaning the chimney, soot and
other deposits may come to fall on the
smoke plate. In cases where the wood
burns too quickly, this may be due
to excessive chimney draught. You
should also check to make sure that
the door seal and ashpan seal is intact
and correctly fitting.
If the stove it generating too little
heat, this may be because you are fi-
ring with wet wood. In this case, much
of the heating energy is used to dry
the wood, resulting in poor heating
economics and an increased risk of
soot deposits in the chimney.
Cleaning the glass
Incorrect firing, for example using
wet wood, can result in the viewing
window becoming covered in soot.
This soot can be easily and effectively
removed by using proprietary stove
glass cleaner.
Distance to
Stove
furnitures from
weight
the stove in
kg
mm
900
420
900
541