Heta Scan-Line Solid C Operating And Installation Instructions

Heta Scan-Line Solid C Operating And Installation Instructions

Hide thumbs Also See for Scan-Line Solid C:

Advertisement

Quick Links

OPERAtING AND INStAllAtION
INStRUCtIONS
SCAN-lINE SOlID C
The scan-line solid c is exempT for use
in smoke conTrol areas when burning dry wood
ECODESIGN READY
www.heta.dk
EN
DANISh DESIGN . DANISh QUAlItY . DANISh PRODUCtION
1

Advertisement

Table of Contents
loading

Summary of Contents for Heta Scan-Line Solid C

  • Page 1 OPERAtING AND INStAllAtION INStRUCtIONS SCAN-lINE SOlID C The scan-line solid c is exempT for use in smoke conTrol areas when burning dry wood ECODESIGN READY www.heta.dk DANISh DESIGN . DANISh QUAlItY . DANISh PRODUCtION...
  • Page 3: Table Of Contents

    The Scan-Line Solid C have been approved according to the EN 13240, NS 3058/3059 and the Scan-Line Solid C is modified so that they are also recommended as exempt for use within smoke control areas (SCA) throughout the UK (see clean air act Appen- dix A).
  • Page 4: Before Installation

    It is important that upon receipt check your Heta product completely and report any damage or defects to your dealer. The packaging must be disposed of as follows: Wood is untreated and able to burn in the stove.
  • Page 5 Solid C high Concrete element 1 x 0023-2507 Concrete element 1 x 0023-2508 1 x 0023-2509 1 x 0023-2509 Heat shield 1 x 1022-0087 Heat shield 2 x 1022-0090 2 x 1022-0090 1 x 1022-0091 1 x 1022-0091 1 x 1022-0094 External air from behind 1 x 0032-0027...
  • Page 6: Accessory Parts

    Accessory Parts Akkumulation External air from below, complete 1511-0033 1 x 0023-0237 - 1011-0275 1511-0032 - 2 x 0023-0237 - 1011-0276 3 x 0023-0237 4 x 0008-1720 3,9x14 4 x 0023-0237 5 x 0008-2301 M4x8 (Solid C High) Solid C Solid High External air from behind (1324 mm) External air from behind (1824 mm)
  • Page 7: Operating Instructions

    Refueling of your stove should be done while there is still a good layer of embers. Distribute The Scan-Line Solid C stoves are designed and the embers with the majority of them to the front. tested to burn extremely cleanly with very little...
  • Page 8: Reduced Burning

    come from the tree, when it is becomes glowing charcoal. If you are looking for less heat out-put, achieve this by fueling with smaller volumes of wood and a lower operating air. You may not completely close the operating air during firing. Be aware that the stove will naturally soot if the operating air is too low.
  • Page 9: Draft Conditions In The Chimney

    • Poorly placed chimney for the surroundings, timal combustion and the highest possible ef- for ex. the ridge and trees may cause ficiency. Heta wood stoves are constructed so turbulence. that it itself provides an optimal blend of com- bustion air. This provides a high efficiency/heat, Good draft occurs when: clean glass and low environmental impact.
  • Page 10: Operational Problems

    burns too quickly, this may be due to excessive Examples of fuel values chimney draft. You should also check to make for different woods and their typical densities sure that the door seal and ash pan seal is intact per cubic meter, specified for 100% wood with and correctly fitting.
  • Page 11: Diagram For The Maintenance

    1.16 Diagram for the maintenance Qualified Stove Owner Technicia Maintenance / Period Before 60-90 1st Year 2st Year Daily Autum days days days Cleaning the chimney (see. Chimney) Cleaning the chimney and stove Cleaning the stoves firebox Cleaning combustion air intake Cleaning of the firebox Checking / switch, gasket for door Checking / changing, gasket for glass...
  • Page 12: Troubleshooting

    1.17 troubleshooting table - applies to all stove types fault cause Troubleshooting solution Inadequate chimney draft. Lighting problems. When the You can test using a lighter whether Improve the chimney. The chimney only has stove is cold, smoke seeps flame is drawn into the combustion sufficient draft when it is hot.
  • Page 13: Cleaning/Replacing Bricks After Chimney Sweeping

    1.18 Cleaning after sweeping or before replacing vermiculite stones Note: it may be necessary to clean/vaccum the holes and air ducts behind the rear stone removal sequence of stones. Replace in reverse order. Starting with Fig. 8.
  • Page 14: Stove Data Table En 13240

    Therefore, the duration of the warranty is 5 years on this product, covering manufactu- rer’s defects, 1 year on paint adhesion defects from purchase date from Heta and a 3 months total warranty for seals, vermiculite and glass from the date of sale from the dealer.
  • Page 15: Parts

    1.21 Parts 34 - 35 - - 36 33 - 11 - - 37 32 - 31 - - 30 10 - - 22 12 - 13 - 14 - 15 - 16 - - 23 x 4 - 24 x 2 - 18 - 25 x 2 - 26 x2...
  • Page 16 pos. no. name Qty. pos. no. name Qty. 0023-0213 Top Back stone, left 21 1513-0123* Closing System 22 1505-0084** Left-hinged door 0023-0215 Left baffle 0023-0214 Right baffle 23 5013-0011 Rep. set glass clips sidelight 0023-0212 Lower back stone, left 24 0021-0066 Side Glass, large 0023-0211 Top back stone, right 25 0023-3010...
  • Page 17: Installation Instructions

    The frame is made of fibreglass-reinforced concrete elements, making it highly resistant to thermal stress. The concrete elements are cast, which means there may therefore be variations in surface and structure. If the concrete elements are damaged, use the repair mortar provided. The frame surfaces can be painted without priming.
  • Page 18: Installation Instructions

    We recommend that you let a 2.2 floor professional Heta dealer install the stove. Alter- You must ensure that the floor can support the natively, you can ask the local chimney sweep weight of the stove and a top-mounted steel before installation.
  • Page 19: Combustion Air

    5 m / hour / m then a ven- beading. Heta A/S stresses that it is of utmost tilator equivalent to 550 mm per kW output will importance that this is done correctly with very be required (4.5 kW x 550 mm = 2475 mm...
  • Page 20: Stovedrawings/Measurments

    2.7 Stovedrawings/measurments Solid C high (8120-0410) Solid C (8120-0310) 2.8 Clearances for installation EN 13 240 The Building materials that are used in safety test and shown in illustrations on this page, has a thermal conductivity of max. (= <0.36 W (m * K) Solid C and Solid C high 1.
  • Page 21: Installation Of The Stove

    Installation of the stove Solid C and Solid C high 3 min. 2 x 1013-1006 ≈ 3 ≈ 3...
  • Page 22 Scan-line Solid C 13 x M6 x 25 0008x1807 13 x M6 x 8 0008-0035...
  • Page 23 Scan-line Solid C high 13 x 13 x M6 x 25 M6 x 8 0008x1807 0008-0035...
  • Page 24: Rear Flue Outlet

    2.10 Rear flue outlet (Accessory 5032-0082 Solid C and 5032-0092 Solid high)
  • Page 25 20 and 21 of the Clean Air Act 1993 by section 15 of the The Scan-Line Solid C high have all been re- Deregulation Act 2015. Similarly, in Scotland ap- commended as suitable for use in smoke con- pliances are exempted by publication on a list by trol areas when burning dry wood logs.
  • Page 26: Connecting External Air Supply From Below

    4. Connecting external air supply from below 5 x M4x8...
  • Page 27: Connecting External Air Supply From Behind

    5. Connecting external air supply from behind...
  • Page 31: Eu Declaration Of Conformity

    Certifikat no. 2237 Manufacturer Heta A/S Ecodesign Adress Jupitervej 22, DK 7620 Lemvig EU Declaration of Conformity E-mail heta@heta.dk Website www.heta.dk DoC Scan-Line Prestige 2237-2017 Telephone +45 9663 0600 Product fiche Model identifier Scan-Line Prestige A, BL, BR, C, Solid C...