  • Page 1 SCAN-LINE95/100 www.heta.dk www.heta.dk...
  • Page 2: Installation Instructions

    Congratulations on your new stove. of specifications and requirements in - We are sure that you will be happy tended to ensure that the materials with your investment, especially if you used are of good quality, that the stove follow the advice and instructions we does not adversely affect the environ- have put together in these operating ment, and hat it is economical to use.
  • Page 3 be less than 175 cm , which corre- sive weight may cause damage on or sponds to a diameter of 150 mm. If a noise from the stove). damper is fitted in the flue gas pipe, Draft conditions there must always be at least 20 cm Poor draft may result in smoke being free passage, even when the damper is emitted from the stove when the door...
  • Page 4: Instructions For Use

    fresh air). fitted. However, by connecting a • Poor smoke extraction (poor draft sealed air inlet to the insert stove’s conditions) due to a cold chimney air intake connectors, the stove can or bad weather conditions can be be supplied with external combustion compensated for by increasing the air flow.
  • Page 5 Regulating the airflow before storing. The pieces of firewood should be of an appropriate length (ap- To adjust combustion airflow, use the prox. 30-40 cm) so that they can lie flat handle at the front under the door. on the bed of embers. If you store your Combustion air flow is fully open when wood outdoors, it is best to cover it.
  • Page 6 ignite more quickly while the door is condary/start-up air supply to smother ajar.) The wood should ignite within a the fire. Call the fire department. very short time (usually 1-3 minutes). Optimal combustion If the door is ajar, close it as soon as For optimal combustion and heating, the fuel is ignited.
  • Page 7: Operational Problems

    Stove data table in accordance with EN 13240 testing Stove Nominal Smoke Fuel Draught Nominal Actual Distance to flama- Distance to Stove furnitures type fluegas stub volume output efficiency ble materials in mm weight from the tempera- tested behind at the stove in mm the stove sides ture c°...
  • Page 8 GUARANTEE Heta stoves are subjected to stringent Damage resulting from incorrect use quality control procedures both throug- Transport costs in connection with repairs hout the production process and im- carried out under guarantee Installati- mediately before delivery to the dealer.
  • Page 9 FITTING EXTERNAL AIR INLET - FROM BELOW Fresh air set - item no. 1515-0013 When the ø100 connector is fitted to the damper, put the ring with Remove stones from combustion the cord around down at the bot- chamber tom. See figure 5. Remove the steel plate at the bot- Carefully replace the damper.
  • Page 10 CLEARING SOOT AFTER SWEEPING OR WHEN RENEWING STONES Note that it may be necessary to clean/vacuum the holes and air duct behind the rear stone. Sequence of removal - stones Remove spark screen and vacuum any ash in the bottom. Baffle: Lift and turn the baffle slightly to one side and carefully remove.
  • Page 11 REAR STONE The rear stone has been devided into two stones. They are kept together with a small fitting on the back side, which is pushed down into the grooves. SCAN-LINE 95/100 WITHOUT PEDESTAL Special conditions regarding Scan-Line 95/100 without pedestal Make sure that the distance from the lower edge of the door to the floor is mini- mum 350 mm.
  • Page 12 TRANSPORTATION SAFETY DEVISE Regarding Scan-Line 100 on a turnable pedestal The screw must be removed before the stove is used/turned!

This manual is also suitable for:

Scan-line100