Load Stored Profile
Result Codes
Load Stored Profile on Start-up
Result Codes
P0873832 Issue 05
The Load Stored ProÞle Command
instructs the CTA 500dm to load all values that are stored in a
proÞle. Value 0 indicates that the factory proÞle should be loaded.
Value 1 indicates that the user proÞle should be loaded.
Any calls in progress are disconnected when you use this command.
The Z command selects the user proÞle (default value 1).The &F
command selects the factory proÞle (default value 0). Using either
command, if no value is speciÞed, the default proÞle is used.
OK Appears when the command is executed.
ERROR Appears when the command could not be executed.
The Load Stored ProÞle on Start-up Command
instructs the CTA 500dm to load all values that are stored in a proÞle
after a power-up or after a DTR reset if &D is set to 3
Interface Control LinesÓ on page 56
Value 0 indicates that the factory proÞle should be loaded at start-up.
Value 1 indicates that the user proÞle should be loaded at start-up. If
no value is speciÞed, the default factory proÞle is used.
OK Appears when the value is recognized or not supplied.
ERROR Appears when the value is invalid or unrecognized.
Z[value]
or
&F[value]
&Y[value]
for the commands).