Viessmann VITOLADENS 300-W Installation And Service Instructions Manual page 88

Wall mounted oil condensing boiler
Table of Contents

Advertisement

Code 2
Heating circuit 1, heating circuit 2, heating...
Coding in the delivered condition
30 % of the max. speed
(only for weather-com-
pensated control units)
E8:1
Only for heating systems
without a heating circuit
with mixer:
Minimum speed of the in-
ternal variable speed
heating circuit pump in
operation with reduced
room temperature sub-
ject to the setting in cod-
ing address "E9" (only for
weather-compensated
control units)
E9:45
Only for heating systems
without a heating circuit
with mixer:
Speed of the internal var-
iable speed heating cir-
cuit pump:
45 % of the max. speed
during operation with re-
duced room temperature
(only for weather-com-
pensated control units)
F1:0
Screed drying not active
F2:8
Time limit for party mode
or external operating pro-
gram changeover via but-
ton: 8 h
Party mode ends automatically in the "Heating and DHW" operating program
*2
when the system changes over to operation with standard room temperature.
88
*2
Possible change
E8:0
Speed subject to the set-
ting in coding address
"E7"
E9:0
Speed adjustable from 0 to
to
100 % of the maximum
E9:100
speed during operation
with reduced room temper-
ature
F1:1
Screed drying adjustable in
to
accordance with 6 selecta-
F1:6
ble temperature/time pro-
files (see page 122)
F1:15
Constant flow temperature
20 °C
F2:0
No time limit for party
mode
F2:1
Time limit adjustable from 1
to
to 12 h
F2:12
(cont.)
*2
*2