Viessmann VITOLADENS 300-W Installation And Service Instructions Manual page 56

Wall mounted oil condensing boiler
Table of Contents

Advertisement

Code 1
General
(cont.)
Coding in the delivered condition
Internal circulation pump function
51:0
Internal circulation pump
always starts when there
is a heat demand
Subscriber no.
77:1
LON subscriber number
Detached house/apartment building
7F:1
Detached house
56
Possible change
51:1
System with low loss head-
er:
When there is a heat de-
mand, the internal circula-
tion pump is only started if
the burner is operational.
Circulation pump is switch-
ed off on expiry of run-on
time
51:2
System with heating water
buffer cylinder:
When there is a heat de-
mand, the internal circula-
tion pump is only started if
the burner is operational.
Circulation pump is switch-
ed off on expiry of run-on
time
77:2
LON subscriber number,
to
adjustable from 1 to 99:
77:99
1 - 4 = Boiler
5 = Cascade
10 - 97 = Vitotronic 200-H
98 = Vitogate
99 = Vitocom
Note
Allocate each number only
once.
7F:0
Apartment building.
Separate adjustment of
holiday program and time
program for DHW heating
possible