Optional Parts; Specifications; Hbc Controller - Mitsubishi Electric PURY-WP-YJM-A Data Book

Table of Contents

Advertisement

1. SPECIFICATIONS

1. SPECIFICATIONS
I.HBC controller
Model name
Number of branch
Power source
Power input
Cooling
(220/230/240) Heating
Current input
Cooling
(220/230/240) Heating
Sound pressure level (measured in anechoice room)
Applicable temperature range of installation site
External finish
Connectable outdoor unit
Indoor unit capacity connectable to 1 branch
External dimension H x W x D
Connectable outdoor unit capacity
Refrigerant piping
High press. Pipe
diameter
(To outdoor unit)
Low press. Pipe
Inlet Pipe
Water piping
diameter
(To Indoor unit)
Outlet Pipe
Field drain pipe size
Net weight
Document
Standard
attachment
Accessory

Optional parts

Note;
1.Works not included:
Installation / foundation work, electrical connection work, duct work, insulation work, power source switch,
and other items are not specified in this specification.
2.The equipment is for R410A refrigerant.
3.Install this product in a location where noise (refrigerant and water noise) emitted by the unit will not disturb the neighbours.
For use in quiet environments with low background noise, position the HBC CONTROLLER at least 5 m away from any indoor units.
4.Install the HBC controller in a place where noise will not be an issue.
5.Attach an expansion tank (field supply).
6.Use copper or plastic pipes for the water circuit. Do not use steel or stainless steel pipework.
Furthermore, when using copper pipe-work use a non-oxidative brazing method.
Oxidation of the pipe-work will reduce the pump life.
7.Install an air purge valve where air will gather in the water circuit.
8.Install a pressure reducing valve and a strainer on the water supply to the HBC controller. Also consider installing a non-return valve (check local regulations).
9.Refer to the databook or the installation manual for the specified water quality.
10.This unit is not designed for outside installation.
11.Always leave the power on or remove the circulation water completely when the power is off for an extended period.
*Do not use the circuit water as drinking water.
12.Do not use ground water or well water.
13.When installing the HBC unit in an environment which may drop below 0 °C, please add antifreeze to the circulating water.
(Refer to the data-book and the installation manual).
14.Use cover caps (field supply, dezincification resistant brass (DZR) or bronze only) on unused branches.
15.Install a sub drain pan (sold separately, PAC-HBC01DP-E). If leakage from underneath the HBC would cause no problem in the installed location,
installation of the sub drain pan is not necessary.
16.The system must be serviced at least once a year.
50 Hz
kW
0.450/0.460/0.470
kW
0.450/0.460/0.470
A
2.89/2.83/2.79
A
2.89/2.83/2.79
dB <A>
°C (D.B.)
(Lower part drain pan: Pre-coated galvanized sheets + powder coating)
(Use a joint pipe (field supply) combining 2 branches when the total unit capacity exceeds P80)
mm
in.
To WP200
mm (in.)
15.88 (5/8)
O.D.
Brazed
mm (in.)
19.05 (3/4)
O.D.
Brazed
mm (in.)
I.D.
mm (in.)
I.D.
mm (in.)
kg (lbs)
1.Reducer
2.Drain Connection pipe (with flexible hose and insulation)
INDOOR UNITS
CMB-WP108V-G
8
220-230-240 V
41
0~32
Galvanized steel plate
PURY-WP200/250YJM-A(-BS)
Model P80 or smaller
300 x 1,600 x 541
11-13/16 x 63 x 21-5/16
To WP250
19.05 (3/4)
Brazed
22.2 (7/8)
Brazed
20 (Rc3/4) screw
20 (Rc3/4) screw
O.D. 32 (1-1/4)
92 (203) [102 (225) with water]
Sub drainpan: PAC-HBC01DP-E
60 Hz
0.450/0.460/0.470
0.450/0.460/0.470
2.89/2.83/2.79
2.89/2.83/2.79
1 - 50