Firmware Warning Messages
WARNING: The processor has failed selftest.
WARNING: One or more memory banks were not
configured due to a SIMM size mismatch or a SIMM
failure. For more details, use the MEMORY
command in the INFORMATION menu.
WARNING: The Bus Converter has failed.
WARNING: FAN FAILURE HAS BEEN
DETECTED. THE SYSTEM WILL BE
POWERING DOWN. PLEASE CALL YOUR
SERVICE REPRESENTATIVE
ERROR: A3342A AP Card must be in bottom slot
only.
ERROR: HSC card in wrong slot. Move to bottom
slot.
Chassis Code Summary
Operating Status (OSTAT) and chassis codes are generated by A-Class server
firmware. OSTAT and chassis codes can be read from stored locations or viewed
'real time' via the HSC Remote Management card.
Chassis codes displayed during selftest only appear at the console. They will appear
on either the ASCII console or the Web console. Below is an example of how
chassis codes appear in response to a 'control b' key sequence:
Chapter 3
A-Class System Service
A-Class Server Trouble Shooting
Description/Action Required
A processor selftest failure requires replacing the
EBU.
Use the MEMORY command in the
INFORMATION menu to determine correct
configuration.
A Bus Converter failure requires replacing the
EBU.
A chassis fan failure requires replacing the EBU.
Move the AP A3342A card to the bottom slot.
A mix of HSC and PCI cards has been detected.
The HSC card must be installed in the bottom
slot.