NOTE
Replace the rubberized feet on the server with plugs provided in the cabinet
mounting adapter kit.
Fill empty cabinets from the top down, with A-Class servers on top. If you are
mounting one or more servers into an empty cabinet, start at the inside top of the
cabinet and count down four of the holes in the columns at each corner to determine
the position of the rails for the first server. When the first rails are installed, continue
to use the four hole requirement as your guide for installing additional A-Class
servers.
Refer to the Rail Kit Installation Sheet (A5214-96001) for instructions necessary to
install rails in the HP computer cabinet.
Mounting the Server To mount the server in the cabinet, follow the procedure
listed below:
Step 1. From the front of the cabinet, slide the server onto the rails. Push the server into the
cabinet until approximately three inches of the server remains protruding from the
front.
Step 2. Install sheet metal nuts on the left and right front columns and align with front
anchor bracket slots.
Step 3. Install the left and right front anchor brackets on each side of the server as follows:
o Insert each hooked tab into its slot on the bottom of the front corner of the
Chapter 2
Cabinet-Mounted A-Class Server System Unpack and Install
server.
A-Class Server Installation
37