HP 9000 A-180 User Manual page 53

Hide thumbs Also See for HP 9000 A-180:
Table of Contents

Advertisement

Power Up the Server
Apply power to the A-Class server by toggling the rocker power switch on the rear
of the server from the 0 position to the 1 position. All of the front panel LEDs will
illuminate for a moment, then turn off. Only the green power LED will remain
illuminated until power is switched off. If the LEDs do not illuminate or the server
does not appear to power on, refer to "Boot HP-UX" (link to A-Class System
Service)
The server will automatically conduct a selftest and, upon completion, the firmware
Main Menu screen will be displayed at the system console. Only the power LED
should be illuminated at this point.
If AUTOBOOT is enabled, the system will automatically try to boot HP-UX from
the PRIMARY PATH. If you want to interrupt the boot process, press any key on the
keyboard within 10 seconds after the message, Hit any key to interrupt
the boot sequence is displayed.
Configuring the integrated A-Class Web Console
CAUTION
The integrated A-Class Web Console is preconfigured with IP address 192.0.0.192.
Power-off any other devices with the same IP address before proceeding with
integrated A-Class Web Console configuration. Each A-Class server must be
configured to the integrated A-Class Web Console with an individual IP address.
Failure to follow this precaution will result in unexpected behavior of the Local
Area Network (LAN).
Configuring The Web Browser Host
NOTE
The A-Class server and the Web Browser Host must be on the same subnet.
Enter the following commands into either a DOS window or UNIX widow on the
host where the browser used to configure the integrated A-Class Web Console
resides:
Step 1. Route add 192.0.0.192 <host IP address>.
Step 2. ping 192.0.0.192.