Heat Distribution Systems Installation (Ac01389 Or Ac01339) - Osburn Stratford CFOB04006 Operating & Installation Instructions Manual

Zero clearance wood inbuilt
Table of Contents

Advertisement

6.3.3

Heat Distribution Systems Installation (AC01389 or AC01339)

Different heat distribution systems can be installed with the Stratford CF:
The hot air gravity distribution kit – modern style with adjustable pipes (AC01389)* is mandatory on the
Stratford CF:
You can also install the optional forced air distribution kit (AC01339)* (see Appendix 1: Optional Forced Air
Distribution Kit (AC01339)*).
* The forced air distribution kit (AC01339) with heat activated system is sold separately and can be
installed only with the hot air gravity distribution kit - modern style with adjustable pipes (AC01389).
C
305 mm MINIMUM
* The measurement between the cross member and
the hot air register applies for the bottom and the
top of the hot air register.
(E) = non-combustible material
34
D*
203 mm MINIMUM
OPERATING & INSTALLATION INSTRUCTIONS FOR STRATFORD CF ZERO CLEARANCE WOOD HEATER
C
305 mm MINIMUM
D
1.52 m MINIMUM

Advertisement