Osburn Stratford CFOB04006 Operating & Installation Instructions Manual page 31

Zero clearance wood inbuilt
Table of Contents

Advertisement

Secure the fresh air intake adapter (A) on
the wood inbuilt jacket using the 4 screws
provided with the kit.
Then, install the flexible pipe* (C) (not
supplied) to the fresh air intake adapter (A)
using one of the adjustable pipe clamps (B).
Secure the other end of the pipe to the
outside wall termination (D) using the
second adjustable pipe clamp (B). The
outside wall termination (D) must be
installed outside of the building.
*Use
the
length
required
for
your
installation while respecting the maximum
length of 9 m. To avoid condensation, it is
recommended to use an insulated pipe long
enough and containing a "P-Trap" loop. This
configuration can be found inside the chase,
but must at all times maintain clearances to
combustibles.
31
OPERATING & INSTALLATION INSTRUCTIONS FOR STRATFORD CF ZERO CLEARANCE WOOD HEATER