5.1.4 Door Alignment
To align, open the inbuilt's door
and
loosen
the
pressures
screws located on the lower
and upper hinges of the door
using a 5/64" (2mm) Allen key
to free the adjustable hinge
rods.
Using a flat screwdriver, turn
the adjustable hinge rods in the
direction shown to adjust the
doors. Tighten all door hinge
pressure screws when they are
at the desired positions.
21
OPERATING & INSTALLATION INSTRUCTIONS FOR STRATFORD CF ZERO CLEARANCE WOOD HEATER