3. Checking the Operations
1) If you are not connecting the Communication
Control Board-A1 or the Interface Board-B1
(not requiring the Power Supply-A1), go to
step 4).
Connect the connector 1 of the Power Supply-
A1 to the connector 2 of the Copy Data
Controller-A1 securely as indicated.
Check to make sure that the cord is in the
groove of the board.
2
Groove of the board.
Figure 5-509
2) Connect the Power Supply-A1 to the power
plug, and check to make sure that LED1 of the
Copy Data Controller-A1 turns ON.
LED1
LED1
LED2
LED3
LED4
LED5
LED6
JC5
J5
6
1
6
SW1 ON
SW5 ON
Figure 5-510
COPYRIGHT © 1996 CANON INC.
Download service manual and resetter printer at http://printer1.blogspot.com
1
SW2
SW3
JA1
JC8
JB2
JC6
JB1
JC9
CPU
IPC
SW4
1
CANON GP215/200 REV.0 JULY 1996 PRINTED IN JAPAN (IMPRIME AU JAPON)
3) Turn ON the copier's main switch, and check
to make sure that LED2 of the Copy Data
Controller-A1 flashes.
Make a copy, and check to make sure that
LED3 flashes during copying operation.
LED2
LED1
LED2
LED4
J5
6
SW1 ON
4) To connect the Communication Board-A1 or
the Interface Board-B1 (requiring the Power
Supply-A1), go to step 5).
Turn ON the copier's main switch, and check
to make sure that LED1 turns ON and LED2
flashes.
Make a copy, and check to make sure that
LED3 flashes during copying operation.
LED1
LED2
LED1
LED2
LED4
JA2
J5
6
SW1 ON
5. INSTALLATION
LED3
LED3
SW2
SW3
LED5
LED6
JC8
JB2
JC5
JC6
JC9
CPU
IPC
SW4
1
6
1
SW5 ON
Figure 5-511
LED3
LED3
SW2
SW3
LED5
LED6
JB2
JC8
JC5
JC6
JC9
CPU
IPC
SW4
1
6
1
SW5 ON
Figure 5-512
JA1
JA2
JB1
JA1
JA2
JB1
5–37