Canon GP200 Service Manual page 129

Hide thumbs Also See for GP200:
Table of Contents

Advertisement

Status Indications by Flashing LED
Flashing intervals
Intervals of 0.5 sec
0.5sec
0.5sec
ON
OFF
Intervals of 2 sec
2sec
2sec
ON
OFF
Intervals of 3 sec
3sec
ON
OFF
Intervals of 5 sec
5sec
ON
OFF
Intervals of 6 sec
6sec
ON
OFF
Intervals of 8 sec
8sec
ON
OFF
Intervals of 10 sec
10sec
ON
OFF
* The same error can occur when the fluorescent lamp has deteriorated over time or fails to turn ON. As
such, if the LED flashes at intervals of 6 sec, check to make sure that the inner side of the glass
around the filament at both ends of the fluorescent lamp has not become black.
COPYRIGHT © 1996 CANON INC.
Download service manual and resetter printer at http://printer1.blogspot.com
3sec
5sec
6sec
8sec
10sec
CANON GP215/200 REV.0 JULY 1996 PRINTED IN JAPAN (IMPRIME AU JAPON)
Classification
Normal
The composite power supply PCB is
operating normally.
Overcurrent
The composite power supply PCB
has detected an overcurrent
because of trapped wiring or an
error in a load in relation to +24VR
or +24VU output.
Low-voltage control
The difference between the setting for
error in standby
+24VR output and the control value in
standby is larger than specified.
Upon detection, error data is sent to
the DC controller PCB. 'E803' will be
indicated on the control panel.
Error in the commu-
An error has occurred in the commu-
nication with the DC
nication between the DC controller
controller PCB
PCB and the composite power supply
PCB, and the communication data is
not renewed for 8 sec or more.
However, LED100 on the DC controller
may not flash or turn ON at times.
'E191' will be indicated on the con-
trol panel.
Low-voltage control
The difference between the setting
error during copying*
of the +24VR output and the actual
control value is more than specified.
Upon detection, error data will be
sent to the DC controller PCB.
'E803' will be indicated on the con-
trol panel.
+5.1V output control
+5.1V output is outside the specified
error
range. All outputs of the composite
power supply PCB will be stopped
so that the display indications on the
control panel will also turn OFF.
Check sum error on
The CPU on the DC controller PCB
the DC controller
has detected a check sum error in the
PCB
communication data twice in a row.
All outputs of the composite power
supply PCB will be stopped.
'E1921' will be indicated on the con-
trol panel.
3. OPERATIONS AND TIMING
Description
3–75