2. HALL Adjustment

For detecting the position of the lens iris and ND filter, adjust AMP
gain and offset.
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value 1
Specified Value 2
Specified Value 3
Specified Value 4
Note1: Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
Note2: When reading or writing the 19 page data, select page: 0, address:
10, and set data: 01, then select 9 page. The 19 page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
"00".
Switch setting:
MODE ......................................................... CAMERA-TAPE
Adjusting method:
Order Page Address Data
1
0
01
2
0
10
3
6
01
4
6
02
5
6
01
Note3: The adjustment data will be automatically input to page: F, address:
13 to 18, 92 and to page: 19, address: 24 to 27.
Not required
Display data of page 1 (Note1)
Adjustment remote commander
F
19 (Note2)
13 to 18, 92
24 to 27
D4 to DC
24 to 2C
D2 to DE
22 to 2E
IRIS display data
ND display data
Procedure
01
Set the data.
00
Set the data.
6D
Set the data, and press PAUSE
button.
Check that the data changes to
"01" within 50 sec. (Note3)
00
Set the data, and press PAUSE
button.
Checking method:
Order Page Address Data
1
0
03
2
0
10
3
6
01
4
6
01
5
1
6
6
01
7
1
8
6
01
9
6
01
10
1
11
6
01
12
1
Processing after Completing Adjustments:
Order Page Address Data
1
0
03
2
0
10
3
6
01
4
0
01
6-22
Procedure
03
Set the data.
00
Set the data.
01
Set the data, and press PAUSE
button.
03
Set the data, and press PAUSE
button.
Check that the IRIS display data
(Note1) satisfies the specified
value 1.
01
Set the data, and press PAUSE
button.
Check that the IRIS display data
(Note1) satisfies the specified
value.2.
6B
Set the data, and press PAUSE
button.
69
Set the data, and press PAUSE
button.
Check that the ND display data
(Note1) satisfies the specified
value 3.
6B
Set the data, and press PAUSE
button.
Check that the ND display data
(Note1) satisfies the specified
value.4.
Procedure
00
Set the data.
00
Set the data.
00
Set the data, and press PAUSE
button.
00
Set the data.