8. V-COM Level Adjustment (PK-58 board)

Set the common electrode drive signal level of LCD to the specified
value.
Mode
Still (Auto (
Subject
Arbitrary
Measurement Point
Pin 8 of CN302 (COM)
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
D6
Specified Value
A = 6.50 ± 0.05V
Adjusting method:
Order Page Address Data
1
0
01
01
2
4
F1
03
3
D
D6
4
D
D6
5
4
F1
00
6
0
01
00
2H
Fig. 5-1-21.
))
Procedure
Set the data.
Set the data.
Change the data and set the V-COM
signal level (A) to the specified
value.
Press PAUSE button.
Set the data.
Set the data.

9. V-COM Adjustment (PK-58 board)

Set the DC bias of the common electrode drive signal of LCD to the
specified value.
If deviated, the LCD display will move, producing flicker and
conspicuous vertical lines.
Mode
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Note1: Perform "Bright Adjustment" and "Contrast Adjustment" before
this adjustment.
Adjusting method:
Order Page Address Data
1
0
01
2
4
F1
3
4
10
4
D
D8
5
D
D8
6
4
10
A
7
4
F1
8
0
01
5-29
Still (Auto (
))
Arbitrary
Check on LCD display
D
D8
The brightness difference between the
section A and section B is minimum.
Procedure
01
Set the data.
01
Set the data.
02
Set the data.
Change the data so that the
brightness of the section A and
that of the section B is equal.
Press PAUSE button.
00
Set the data.
00
Set the data.
00
Set the data.
A
B
A
B
B
A
A
B
Fig. 5-1-22.