Changing The Bagstop Quantity - DeLaRue MACH 12 User Manual

Coin sorter and counter mics control w/rs232 interface
Table of Contents

Advertisement

Operating the sorter
changing the bagstop quantity (not at bagstop)
COIN
BAGSTOP
.10
.01
.05
.25
1.00
.50
USE KEYPAD TO
ENTER BAGSTOP / #
60
Bagstop quantities may be set (reset) at any
time the sorter is at rest (no counting / sorting).
1. Press the MOTOR ON / OFF Key on the
Control to stop the Sorting Motor.
2. Press the direct access BAGSTOP Icon Key
(
). The Display will show the bagstop
settings for all coins.
# OF STOPS
500.00
25
50.00
10
200.00
25
1000.00
10
1000.00
50
1000.00
30
FIGURE #55
BAGSTOP ENTRY SCREEN
3. Cycle the bagstop (left) DOWN ARROW
Icon Key (
setting.
4. Enter the new setting using the Numeric
Keypad followed by the "Enter" key.
Note: To eliminate a bagstop at a specific
station, set that station to "0".
Note: If quantities are changed during coin
processing, it is important that the number of
coins currently in the coin bag must be less
than the new bagstop quantity. Check (and
clear if necessary) the bag count quantity of
the selected coin before selecting the new
bagstop setting, then proceed as follows:
5. Press the HOME Icon Key (
to the HOME SCREEN.
6. Press the MOTOR ON / OFF Key to start
the Sorting Motor.
) to highlight the desired bag
) to return

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents