initializing the control for remote display operation
. ,
/
PROGRAMMING MODE
NEXT
PAGE
HOME PROGRAMMING SCREEN
The Sorter must be "told" that a Remote Display
is connected, so that the proper communication
link can be established.
Note: The sorter must be in programming
mode. To enter the programming mode, per-
form the steps below.
A. Connect Remote Display to Port #3 at
rear of Sorter.
B. Turn Sorter Keyswitch to the unlock posi-
tion.
C. Hold UPPER ICON SELECT Key down
while turning Sorter ON.
D. The Display will show:
$.00
1234
FIGURE #104
E. Press the NEXT PAGE Icon Key.