3.18 Log Utilities
3.18.1 Program Description
This function logs error information generated while a test is in progress and stores the results in
RAM. This function can store data on a floppy disk or output the data to a printer. If the power
switch is turned off, the error information will be lost. The error information is displayed in the
following order:
1.
Error count (CNT)
2.
Test name (TS-NAME)
3.
Subtest number (TS-NAME)
4.
Pass count (PASS)
5.
Error status (STS)
6.
FDD/HDD or memory address (ADDR)
7.
Write data (WD)
8.
Read data (RD)
9.
HDC status (HSTS)
10.
Error status name ([ERROR STATUS NAME])
3.18.2 Operations
1.
Select the Log Utilities function by typing 5 and pressing Enter from the DIAGNOSTICS
MENU. Error information will now be logged into RAM or on the floppy disk. The error
information is displayed in the following format.
XXXXX ERRORS
CNT TS-NAME PASS
001 FDD 02 0000
001 FDD 01 0000
Subtest number
Test name
Error count
[[ 1:Next,2:Prev,3:Exit,4:Clear,5:Print,6:FD Log Read,7:FD Log Write ]]
3-42
STS
ADDR
103 00001
180 00001
Address
Error status
Pass count
WD RD HSTS [ERROR STATUS NAME ]
00 00
FDD - WRITE PROTECTED
00 00
FDD - TIME OUT ERROR
HDC status
Read data
Write data
Error status name