When the rollers are replaced, the counter
must be reset.
To reset the counter, select "Start → Set-
tings → Control Panel → Scanner and
Camera" to display the "Properties"
screen for this machine, and click the
"Reset" button for the counter.
Figure 1-602
b. Roller unit
Removal
1) Push the OPEN knob from both sides and
open the upper unit slowly.
Figure 1-603
COPYRIGHT © 2005 CANON ELECTRONICS INC.
2) Raise the roller locking lever.
3) Hold the roller unit with your fingers and
4) Detach the right side of the roller unit first
CANON DR-2580C FIRST EDITION APR. 2005
CHAPTER 1 GENERAL DESCRIPTION
Figure 1-604
slide the locking lever to the right.
Figure 1-605
and remove the roller unit.
Figure 1-606