11. Counter
This mode is used to display/change total
count (cumulative number of feed sheet) and
display/change the number of document jams.
When [Counter] is selected on the service
screen, the counter screen is displayed.
Figure 5-218
The contents of display are as follows:
•
ADF Count
Indicates total count of the main unit.
FlatBed Count
•
Indicates the number of scan of the flatbed
unit.
P01_Jam Count
•
Indicates the number of early reach jams.
P02_Jam Count
•
Indicates the number of residual jams.
P03_Jam Count
•
Indicates the number of fast feed jams.
The "Total Count" shown at the bottom of
the service screen is the total of "ADF Count"
and "FlatBed Count".
When the [Set] button on the right or the
[Set] on the lower right of the screen is se-
lected after the value is changed, the changed
value is determined.
To close the screen, press the [Close]
button.
COPYRIGHT © 2005 CANON ELECTRONICS INC.
control PCB is replaced. Therefore, inputting
the values again is required after the re-
placement. If the values before the replace-
ment are not clear, it is better to input the
recommended values.
CANON DR-2580C FIRST EDITION APR. 2005
CHAPTER 5 TROUBLESHOOTING
These values might be changed if the
5-11