ALERT SETTING MENU { CHANGE TELEMETRY ALERTS }
The ALERT SETTING menu allows you to change the values at which the different Telemetry Alert alarms will sound. For
example, you can change the Temperature Alert value for Temperature 1 to alert you when your nitro engine's cylinder head
temperature is getting too hot or you can change the Voltage Alert value to alert you when your receiver battery is getting too
low for proper servo function.
When the Alert value is reached, the Telemetry Alert alarm will sound and the Condition LED will flash. The audible portion
of the Telemetry Alert alarm can be cleared by pressing the BACK key or the ENTER key.
Changing the Telemetry Alert Alarm Values:
1) From within the TELEMETRY menu, press the UP or DOWN keys to highlight the

ALERT SETTING menu.

2) Press the ENTER key to open the ALERT SETTING menu, then press the UP or DOWN
keys to highlight the Alert value you would like to change. Choose from T1 ALERT
(Temperature 1), T2 ALERT (Temperature 2) or VOLT ALERT (Receiver Voltage).
3) Press the ENTER key, then Press the UP or DOWN keys to choose the desired
Alert value.
ALERT SETTING T1 ALERT and T2 ALERT setting range is 68ºF to 302ºF (0ºC to
150ºC). The default setting is 212ºF (100ºC). ALERT SETTING VOLT ALERT setting
range is 3.0v to 9.0v. The default setting is 3.8v.
Changing the Hold Time Value:
The Hold Time value allows you to program a Voltage Alert delay to prevent voltage drops under load from falsely alerting you
to a low voltage situation. A higher Hold Time value makes the Voltage Alert alarm function more steady.
1) From within the ALERT SETTING menu, press the UP or DOWN keys to highlight
HOLD TIME 1.0sec.
2) Press the ENTER key, then press the UP or DOWN keys to choose the desired Hold
Time value. Increasing the Hold Time value will reduce the chance of voltage drops
under load causing the Voltage Alert alarm to sound.
ALERT SETTING HOLD TIME setting range is 0.0sec to 5.0sec. The default setting is 1.0sec.
TELEMETRY SETTING MENU { CHANGE TELEMETRY SETTINGS }
The TELEMETRY SETTING menu allows you to turn the Telemetry System ON and OFF, change the Telemetry Log Step value
to customize the interval at which Telemetry Data is recorded, change the Telemetry Temperature values between Fahrenheit
and Celsius, and change the RPM Ratio value to be able to read actual motor or engine RPM even though your RPM sensor
may be mounted to your model's spur gear and not to your motor's pinion gear or your engine's flywheel.
Turning the Telemetry System ON and OFF:
1) From within the TELEMETRY menu, press the UP or DOWN keys to highlight the
TELEMETRY SETTING menu.
52
TELEMETRY
TELEMETRY
Section Continued on Next Page