Setting mode and check mode/

The following items can be set and checked in the setting mode and check mode. (No setting or checking operations can be
performed while water is running through the Alkaline Ionizer.)
The settings established when purchased can be used for this mode.
Control panel
Return button
Press this to return to the previous screen.
After the settings are completed, the previous screen will not be
restored even when the button is pressed.
Items which can be set
Stronger, Standard or Milder for
"pH fine adjustment"
"Continue mode" ON and OFF
"Water output buzzer" ON and
OFF
"Weak acidic buzzer" ON and
OFF
"Alkaline priority" ON and OFF
"Buzzer volume" High, Medium
and Low
"Electrolysis Signal" ON and
OFF
Measurement condition setting
Items which can be checked/
Optional accessories
Setting check
Selector button/
The setting mode and check mode is started by pressing this button for 1 second.
Enter button
The pH standard set in the "Alkaline" and "Weak acidic"
water quality selector buttons can be adjusted in 3 steps.
When OFF is set, the "Continue" mode is released, and the
continue lamp (see page 35) goes off.
When OFF is set, the buzzer does not beep during the water
output count.
When OFF is set, the buzzer does not beep while weak
acidic water is selected.
When OFF is set, the "Alkaline" setting is not restored after
using purified water and turning off the faucet.
The buzzer volume can be adjusted in 3 steps.
When OFF is set, the electrolysis signal (see page 31) does
not light.
This setting is performed to improve the accuracy of the
water output display (see page 44).
The model number of the optional replacement cartridge can
be checked.
The settings established in the setting mode can be
checked.
Note
The settings and checks will be stopped when:
None of the buttons has been operated for 2 or
more minutes.
Water is run through the Alkaline Ionizer.
One of the water quality selector buttons has been
pressed.
Setting method
page/
42 – 43
54
55
55
56
57
57
46 – 49
Check method
Default settings
Standard
ON
ON
ON
ON
Medium
ON
page/
58
59
53

Advertisement

Table of Contents
loading