Installing the Alkaline Ionizer (continued)
1
After completing the preparations,
connect the water supply hose.
q Remove the hose fastening nut from the bypass
selector, and pass the hose through the nut.
e Tighten up the hose fastening nut securely.
Do not use any tools for this job (since the host
fastening nut may be damaged).
4
Install the acidic water stand.
Connect the hoses as instructed on the label.
Do not place a waste container or other such
objects underneath the acidic water stand.
q Insert the acidic water and drain hoses.
Acidic water
stand
w Attach the stand to the side of the sink.
(If the suction disc slips off, stick the
mounting disc onto the side of the sink.)
20
w Insert the water supply
hose into the bypass
selector as far as it will go.
OK
Acidic water and
drain hoses
Light gray
Dark gray
Label
Adhere to the
side of the sink.
Mounting
disc
2
NG
Gap
Installation position
Main spout
Height difference
Acidic
water spout
The acidic water spout must be below the
level of the bottom of the unit or the difference
in height between the main spout and acidic
water spout must be greater than 10 cm and
less than 50 cm (so that the appropriate pH
level (ion concentration) is achieved).
How to remove the acidic water stand
qHold here
Secure the water supply
hose
(using the hose strap)
wDetach here
Bottom
of unit