Maintenance; Removal Of The Burner Assembly (Manual Control Models); Removal Of The Piezo Igniter (Manual Control Models) - Flavel Windsor Installation, Maintenance & User Instructions

Table of Contents

Advertisement

Servicing Notes
Servicing should be carried out annually by a competent person such as a GAS
SAFE registered engineer. This is a condition of the Flavel guarantee
schemes.
The service should include visually checking the chimney and fire opening for
accumulations of debris and a smoke test to check for a positive up-draught in the
chimney. The Oxy-pilot must also be replaced as a condition of the guarantee.
The condition of the coals / pebbles should be checked and if necessary the
whole set should be replaced with a genuine replacement set.
The burner assembly is designed to be removed as a complete unit for ease of
access. After any servicing work a gas tightness check must always be
carried out.
Manual Control Fires – For Diagrams refer to Section 2
4.1
Removing the burner assembly from the fire.
4.1.1
Prepare work area (lay down dust sheets etc.)
4.1.2
Remove the trim. Remove the fret / ash pan cover or
contemporary trim out of the way and put them in a safe location.
Remove the loose coals or pebbles from the fuel bed.
Remove the fuelbed matrix.
4.1.3
Isolate the gas supply and remove the inlet pipe from the appliance
inlet elbow. Unscrew and remove the two screws which retain the
burner at the base. Lift the burner retaining tabs from the rear of the
firebox & remove the burner assembly from the fire.
4.1.4
To refit the burner assembly. Push the retaining tabs into the rear panel
of the firebox and secure the burner at the base of the control panel
with two screws. Refit the gas supply pipe and carry out a gas
tightness test. Refit the coals or pebbles referring to section 3 for the
correct layout. The trim and ash pan cover or contemporary trim can
now be re-positioned.
4.2
Removing the Piezo Igniter
4.2.1
Remove the burner assembly as in section 4.1
4.2.2
Disconnect the ignition lead from the piezo and unscrew the
retaining nut on the rear of the control panel. Withdraw the piezo from
the front of the control panel. Re-assemble in reverse order and carry
out a gas tightness test.
SECTION 4

MAINTENANCE

28

Advertisement

Table of Contents
loading

This manual is also suitable for:

Stirling plus

Table of Contents