Flavel Windsor Installation, Maintenance & User Instructions page 16

Table of Contents

Advertisement

Fig. 11
2.2.12
Evenly tighten the tensioning nuts to tension both cables and pull the
fire snugly against the wall. Do not overtighten, it is only necessary to
pull the seal up against the sealing face of the wall, it does not need to
be compressed. Check that there are no gaps behind the seal.
2.2.13
With the fire securely in place, if a concealed gas connection has been
made through either of the access holes in the sides of the fire, the
holes should be closed around the pipe to prevent leakage of air
through the gap around the pipe.
2.2.14
Refit the burner. Fit the two retaining screws and check that the burner
is correctly locked into position.
2.2.15
Before making the final gas connection, thoroughly purge the gas
supply pipework to remove all foreign matter, otherwise serious
damage may be caused to the gas control valve on the fire.
16

Advertisement

Table of Contents
loading

This manual is also suitable for:

Stirling plus

Table of Contents