14.2 Setting the armature of the thread cutter magnet
Fig. 48: Setting the armature of the thread cutter magnet
(1) - Block
(2) - Pull rod
(3) - Roller
Proper setting
When the magnet is at rest, the distance between the roller (3) and the
highest point of the control cam (4) must range between 0.2 and 0.3 mm.
To check the armature of the thread cutter magnet:
1. Slide the pull rod (2) with the block (1) all the way to the left.
2. Check the distance between the roller (3) and the control cam (4) using
To set the armature of the thread cutter magnet:
3. Turn the nut (6) on the armature (5).
4. Check the setting and correct it if necessary.
66
①
②
③
a feeler gage.
⑥
④
⑤
(4) - Control cam
(5) - Armature
(6) - Nut
Service Instructions 667 - 00.0 - 04/2016
Thread cutter