Environmental/electrical requirements

Environmental requirements
Operating temperature
Humidity
Altitude
Heat dissipation
System controller
Peripheral cabinet (fully configured)
Printer
System controller
Printer
XEROX 4635 LASER PRINTING SYSTEM INSTALLATION PLANNING GUIDE
Your 4635 LPS has important environmental and electrical
requirements that must be accommodated. These requirements
are summarized in the table below. For further details on
electrical requirements, refer to the following voltage charts and
wiring diagrams.
Table 3-6.
4635 environmental and electrical requirements
Recommended:
Minimum:
Maximum:
Recommended:
Minimum:
Maximum:
Normal:
Maximum:
3,754 Btu per hour
3,195 Btu per hour
Operating:
Standby:
(fuser on)
Energy Saver:
U.S. and Canada, 60 Hz:
International, 50 Hz:
U.S. and Canada, 60 Hz:
International, 50 Hz (WYE):
International, 50 Hz (DELTA):
74° F ± 4° F/24° C ± 4° C
54° F/14° C
85° F/29° C
45% ± 10%
15%
85%
Up to 6,000 feet/1830 m above sea
level
9,000 feet/2743 m above sea level
28,140 Btu per hour
4,454 Btu per hour
2,7000 Btu per hour
208/240 VAC (1 phase) or 208/220
VAC (Line 1 to Line 2);
15 amp service
NEMA 6-15R or ANSI C73, 20R
KVA 1.1 (operating)
200/230 VAC (1 phase)
15 amp service;
Power connector per local codes
120/240 VAC or 120/208 VAC;
50 amp service;
NEMA 14-50R
KVA 7.3 (operating)
380, 400, 415 VAC (3 phase, 5 wire);
20 amp service (WYE)
220, 230, 240 VAC (3 phase, 4 wire);
30 amp service (DELTA)