Environmental/electrical requirements

Environmental requirements
Operating temperature
Humidity
Altitude
Heat dissipation
System controller
Peripheral cabinet (fully configured)
Printer
System controller
3-16
Your DocuPrint 96/DocuPrint 96MX LPS has important
environmental and electrical requirements that must be
accommodated. These requirements are summarized in the table
below. For further details on electrical requirements, refer to the
following voltage charts and wiring diagrams.
Table 3-6.
DocuPrint 96/DocuPrint 96MX Environmental and
electrical requirements
Recommended:
Minimum:
Maximum:
Recommended: 4
Minimum:
Maximum:
Normal:
Maximum:
Operating:
Standby:
Operating:
Standby:
Operating:
Standby:
U.S. and Canada, 60
Hz:
International, 50 Hz:
XEROX DOCUPRINT 96/DOCUPRINT 96MX LPS INSTALLATION PLANNING GUIDE
72° F ± 4° F/22° C ± 2° C
60° F/15.5° C
80° F/29.5° C
45% ± 10%
15%
85%
Up to 6,000 feet/1830 m above sea level
9,000 feet/2743 m above sea level
4,354 Btu per hour
2,485 Btu per hour
3,195 Btu per hour
1,775 Btu per hour
28,140 Btu per hour
4,454 Btu per hour
208/240 VAC (1 phase) or 208/220 VAC
(2 phase)
15 amp service
NEMA 6-15R or ANSI C73, 20R
KVA 1.1 (operating)
200/240 VAC +/-10%
15 amp service;
Power connector per local codes