Correcting the medium feed rate [MEDIA COMP.]

When the medium type or heater temperature is changed, the amount of medium feed changes. Be
sure to correct dot positions.
If the correction value is not appropriate, stripes may occur in the plotting, disturbing neat plotting.
• When in use of a roll medium, the back side of roll medium will loosen after
executing media comp., for the medium returns to the plot original point.
CORRECTING PATTERN
Plot two bands.
Adjust the plot density so that the boundary of the two bands is plotted with an even density,
Setting value
: -255 - 255
Correction value is too large
Correction value is too small
Second band
First band
Get between lines
Overlap
- 2.18 -
Out put direction