Outdoor Unit; Rk(X)S25/35E2V1B - Daikin FLXS-BAVMB Service Manual

Floor / ceiling suspended dual type ba-series
Hide thumbs Also See for FLXS-BAVMB:
Table of Contents

Advertisement

Outdoor Unit

2. Outdoor Unit

2.1

RK(X)S25/35E2V1B

Connectors and
PCB (1): Filter PCB
Other Parts
1) S11
2) HL1, HN1, S
3) E
4) HC1, HC2
5) HR1
6) FU3
7) V2, V3
PCB (2): Main PCB
1) S10
2) S20
3) S30
4) S40
5) S70
6) S80
7) S90
8) HC3, HC4
9) HR2
10)FU1, FU2
11)LED A
12)V1
13)J5
14)J8
15)SW1
17
Connector for main PCB
Connector for terminal board
Terminal for earth
Connector for main PCB
HL2, HN2
Connector for reactor
Fuse (20 A, 250 V)
Varistor
Connector for filter PCB
Connector for electronic expansion valve coil
Connector for compressor
Connector for overload protector
Connector for fan motor
Connector for four way valve coil
Connector for thermistors
(outdoor temperature, outdoor heat exchanger, discharge pipe)
Connector for filter PCB
HL3, HN3
Connector for reactor
Fuse (3.15 A, 250 V)
LED for service monitor (green)
Varistor
Jumper for improvement of defrost performance
Refer to page 218 for detail.
Jumper for facility setting
Refer to page 217 for detail.
Forced cooling operation ON/OFF switch
Printed Circuit Board Connector Wiring Diagram