Outdoor Unit - RK(X)S25/35G2V1B
Step
3. Remove the fan motor.
Remove the washer-
1
fitted nut of the outdoor
fan.
Remove the outdoor
2
fan.
Cut the clamp.
3
159
Procedure
Outdoor fan
D-cut
Points
The screw has reverse
winding.
Nut size: M6
(R14200)
When reassembling, align
mark of the outdoor fan
with D-cut section of the
motor shaft.
(R7197)
(R7198)
Removal Procedure
SiBE05-722_B
10 mm
(R12236)