Daikin FLXS-BAVMB Service Manual page 236

Floor / ceiling suspended dual type ba-series
Hide thumbs Also See for FLXS-BAVMB:
Table of Contents

Advertisement

Wiring Diagrams
RK(X)S25/35G2V1B
FIELD WIRING.
N=1
indoor
X1M
Z3C
1
L
1
BLK
HN1
2
WHT
N 2
3
3
RED
L
N
Z2C
N=2
outdoor
NOTE
1. REFER TO THE NAMEPLATE FOR THE POWER REQUIREMENTS.
C5, C6, C119
: CAPACITOR
DB1, DB2
: DIODE BRIDGE
FU1, FU2, FU3
: FUSE
IPM1
: INTELLIGENT POWER MODULE
L
: LIVE
L1
: COIL
L1R
: REACTOR
M1C
: COMPRESSOR MOTOR
M1F
: FAN MOTOR
MRCW, MR30, MRM10, MRM20 : MAGNETIC RELAY
N
: NEUTRAL
Q1L
: OVERLOAD PROTECTOR
RK(X)S25/35G2V1B9, RXS25/35J2V1B
FIELD WIRING.
indoor
N=2
X1M
Z3C
1
L 1
BLK
2
N
2
WHT
3
3
RED
L
N
Z2C
N=2
outdoor
NOTE
1.REFER TO THE NAMEPLATE FOR THE POWER REQUIREMENTS.
C5, C6, C119
: CAPACITOR
DB1, DB2, DB3
: DIODE BRIDGE
FU1, FU2, FU3
: FUSE
IPM1, IPM2
: INTELLIGENT POWER MODULE
L
: LIVE
L1
: COIL
L1R
: REACTOR
M1C
: COMPRESSOR MOTOR
M1F
: FAN MOTOR
MRCW, MR30, MRM10, MRM20 : MAGNETIC RELAY
N
: NEUTRAL
Q1L
: OVERLOAD PROTECTOR
225
MRM20
FU3
20A
HL1
L1
MRM10
V2
S
V3
MR30
SA1
E1
PCB1
E2
MR30_A
MR30_B
4
PCB1, PCB2
PTC1
S10, S11, S20, S30,
S40, S50, S70, S80,
S90, HL3, HN3
R1T, R2T, R3T
SA1
FU3
20A
AC1
L1
AC2
MRM10
V2
S
V3
FU1
MR30
3.15A
SA1
E1
E2
MR30_A
MR30_B
PCB1
BLK
BLK
4
1
X12A
PCB1, PCB2, PCB3
S10, S11, S20, S40, S50
S70, S80, S90, S100, S110
HL3, HN3, X11A, X12A
R1T, R2T, R3T
SA1
ORG
L1R
HR1
HR2
ORG
HN3
HN2
BLU
HL3
HL2
GRY
FU1
1
WHT
9
3.15A
BLK
BLK
V1
BLK
S11
BLK
S10
BLK
BLK
BLK
9
BLK
1
2
S50
1
S20
S40
BLK
1
6
2
BLK
1
1
3
S80
M
IN CASE OF
Y1E
Q1L
COOLING ONLY
TYPE
: PRINTED CIRCUIT BOARD
V1, V2, V3
: THERMISTOR PTC
X1M
Y1E
Y1R
: CONNECTOR
Z1C, Z2C, Z3C : FERRITE CORE
: THERMISTOR
: SURGE ARRESTER
MRM20
WHT
L1R
HR1
BRN
HN3
HN2
HA1
HA2
BLU
GRY
HL3
HL2
ORG
1
1
WHT
V1
BLK
PCB2
BLK
BLK
S11
S10
BLK
BLK
BLK
BLK
9
9
BLK
MRCW
S50
S100
S20
3
1 1
2
1
6
2
1
3
1
S80
M
S110
IN CASE OF
SW1
COOLING ONLY
Y1E
PCB3
TYPE
SW1
: PRINTED CIRCUIT BOARD
V1, V2, V3
X1M
Y1E
: CONNECTOR
Y1R
: THERMISTOR
Z1C, Z2C, Z3C
: SURGE ARRESTER
DB1
~ +
+
C5
DB2
-
~ -
+
~ +
C118 3.15A
-
+
C6
~ -
-
PCB2
MRCW
S90
S70
S80
1
1
3
1
6
1
2 3
Y1R
IN CASE OF
HEAT PUMP
TYPE
R1T R2T R3T
(OUTDOOR)
(DISCHARGE)
(CONDENSER)
: VARISTOR
: TERMINAL STRIP
: ELECTRONIC EXPANSION VALVE COIL
: REVERSING SOLENOID VALVE COIL
: PROTECTIVE EARTH
DB1
HR2
~ +
+
C5
DB2
_
_
~
+
~ +
C119
_
+
C6
_
_
~
Q1
FU2
DB3
3.15A
~ +
_
~
+
S90
S40
S80
3
1
1
6
2
1
1
4
7
Y1R
Q1L
R1T
R2T
R3T
(OUTDOOR)
(DISCHARGE)
(CONDENSER)
: FORCED OPERATION SWITCH
: VARISTOR
: TERMINAL STRIP
: ELECTRONIC EXPANSION VALVE COIL
: REVERSING SOLENOID VALVE COIL
: FERRITE CORE
: PROTECTIVE EARTH
SiBE05-722_B
IPM1
+
FU2
-
W V U
S30
1
3
4
7
Z1C
M
V
1~
N=4
M1F
W
U
M1C
3D058684B
IPM1
+
_
W V U
IPM2
_
S70
X11A
10
11
12
13
Z1C
MS
V
3~
N=3
U
W
MS
3~
M1F
M1C
3D065704B
Appendix

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents