Outdoor Unit - RK(X)S25/35E2V1B
Step
6
Remove the 4 screws
and remove the fan
motor.
Remove the 2 screws
7
and remove the fan
motor fixing frame.
137
Procedure
Fan motor
Fan motor fixing frame
Points
M4×16
(R3250)
(R3251)
Removal Procedure
SiBE05-722_B