OH08-1
4. Connect the relay harnesses which were connected to the transmission PC-board (2) in step 1. as follows.
Relay harness – long (3) to connector X24A on the indoor unit PC-board
Relay harness – short (4) to connector CN1/X1A on the light receiver assembly (1)
After making these connection, clamp down relay harness – long (3) and relay harness – short (4) relay
harnesses using the included clamp (7).
Connect firmly to
the connector.
(4) Attaching the receiver label
Remove label on the front grill. Detach the adhesive.
Attach the receiver label (6) as the main indoor unit.
Following the installation manual that came with the main indoor unit, attach the front grill.
Control Systems
Relay harness
– short (4)
Connect firmly to
the connector.
Connector (CN1/X1A)
Light receiver assembly (1)
Label
Remote Controller (Wireless Type)
Connector (X24A)
(Black)
Indoor unit PC-board
Relay harness – long (3)
Clamp (7)
Cut off any excess
material after tightening.
Receiver Label (6)