Daikin OH08-1 Instruction Manual
Hide thumbs Also See for OH08-1:

Advertisement

OH08-1
Part 1 Introduction ........................................................................ 1
1. Introduction .............................................................................................2
Part 2 Control Systems ................................................................. 3
1. Remote Controller (Wired Type) .............................................................5
2. Remote Controller (Wireless Type).......................................................10
3. Simplified Remote Controller ..............................................................182
4. Remote Controller for Hotel Use .........................................................186
5. Adaptor for Wiring ...............................................................................191
6. Wiring Adaptor for Electrical Appendices (1) (2) .................................200
7. Installation box for adaptor PCB .........................................................214
8. Interface Adaptor for SkyAir Series.....................................................225
9. External Control Adaptor for Outdoor Unit ..........................................228
10.Remote Sensor (For Indoor Temperature)..........................................236
11.DIII-NET Expander Adaptor ................................................................238
12.Central Remote Controller ..................................................................242
13.Electrical Box with Earth Terminal ......................................................273
14.Unified ON/OFF Controller..................................................................275
15.Wired Remote Controller with Weekly Schedule Timer ......................282
16.Set Back Time Clock...........................................................................289
17.Noise Filter (For Electromagnetic Interface Use only) ........................301
18.Schedule Timer ...................................................................................304
19.Residential Central Remote Controller................................................313
20.Unification Adaptor for Computerized Control.....................................325
21.Wiring Adaptor for Other Air-Conditioner ............................................329
22.Interface for use in BACnet
23.Interface for use in LONWORKS
24.Optional DIII Board..............................................................................344
25.Optional Di Board................................................................................347
26.Optional DIII Ai Unit.............................................................................350
27.intelligent Manager..............................................................................353
28.intelligent Touch Controller .................................................................360
29.Parallel Interface .................................................................................376
Part 3 Indoor Units .................................................................... 393
1. FXC (Q)
2. FXFQ
3. FXZQ
4. FXK (Q)
5. FXD(Q)
Table of Contents
- Ceiling Mounted Cassette Type (Double Flow) - ..............................395
- Ceiling Mounted Cassette Type (Round Flow) - ...............................404
- 600×600 Ceiling Mounted Cassette Type (Multi Flow) - ...................439
- Ceiling Mounted Cassette Corner Type -..........................................451
- Slim Ceiling Mounted Duct Type - ....................................................480
®
...............................................................331
®
......................................................337
i

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OH08-1 and is the answer not in the manual?

Questions and answers

Summary of Contents for Daikin OH08-1

  • Page 1 OH08-1 Part 1 Introduction ................ 1 1. Introduction .....................2 Part 2 Control Systems ..............3 1. Remote Controller (Wired Type) .............5 2. Remote Controller (Wireless Type)............10 3. Simplified Remote Controller ..............182 4. Remote Controller for Hotel Use ............186 5. Adaptor for Wiring ................191 6.
  • Page 2 OH08-1 6. FXYD - Ceiling Mounted Low Silhouette Duct Type -........481 7. FXS (Q) / FXYB - Ceiling Mounted Built-In Type -............482 8. FXM (Q) - M (A) - Ceiling Mounted Duct Type - ............513 9. FXH (Q) - Ceiling Suspended Type -..............529 10.FXA (Q)
  • Page 3 OH08-1 Part 1 Introduction 1. Introduction .....................2 Publication History of Option Handbook..........2 Introduction...
  • Page 4 Introduction OH08-1 1. Introduction Publication History of Option Handbook The following Optional Accessories have been added to OH06-1 (Previous Option Handbook) Additional Contents / Revised Contents Page BRC7F634F/BRC7F635F Remote Controller (Wireless Type) BRC4C65/BRC4C66 Remote Controller (Wireless Type) KRP1C63 Adapter for Wiring...
  • Page 5 OH08-1 Part 2 Control Systems 1. Remote Controller (Wired Type) .............5 BRC1C62 ....................5 2. Remote Controller (Wireless Type)............10 BRC7C62 / BRC7C67 (for FXC(Q)) .............10 BRC7E61W / BRC7E65 (For FXF)............28 BRC7F634F / BRC7F635F (For FXFQ-P)..........47 BRC4C61 / BRC4C62 / BRC4C63 / BRC4C64 (for FXK(Q), FXD(Q), FXDYQ, FXS(Q), FXM, FXMQ-M(A), FXL(Q), FXN(Q), FXYD, FXYB) .................70...
  • Page 6 OH08-1 13.Electrical Box with Earth Terminal ............273 13.1 KJB212A / KJB311A / KJB411A............273 14.Unified ON/OFF Controller..............275 14.1 DCS301BA61 ..................275 15.Wired Remote Controller with Weekly Schedule Timer ......282 15.1 BRC1D61 ...................282 16.Set Back Time Clock................289 16.1 BRC15A61..................289 17.Noise Filter (For Electromagnetic Interface Use only) ......301 17.1 KEK26-1 .....................301...
  • Page 7: Oh08

    OH08-1 Remote Controller (Wired Type) 1. Remote Controller (Wired Type) BRC1C62 1.1.1 Features Operation Functions with HRV BRC1C62 ON / OFF Operation with Air Conditioner Independent operation in intermediate season Ventilation mode change over (Auto / HRV / Normal) Air flow change over (Auto / High / Low)
  • Page 8: Part 2 Control Systems

    Remote Controller (Wired Type) OH08-1 1.1.3 Name and Function C: 3P171361-1 1. On/off button 15.Timer on/off button Press the button and the system will start. Press the button 16.Inspection/test operation button again and the system will stop. This button is only used by qualified service persons for 2.
  • Page 9: Remote Controller (Wired Type)

    OH08-1 Remote Controller (Wired Type) 1.1.4 Installation 1.Remove the upper part of remote controller. Insert minus screwdriver into the slots in the lower part of remote controller (2 places), and remove the upper part of remote controller. The PC board is mounted in the upper part of remote controller.
  • Page 10 Remote Controller (Wired Type) OH08-1 3.Wire the indoor unit. NOTE Connect the terminals on top of the upper part of When wiring, run the wiring remote controller (P1, P2), and the terminals of the away the power supply wiring in indoor unit (P1, P2).
  • Page 11 OH08-1 Remote Controller (Wired Type) 1.1.5 Field Setting If optional accessories are mounted on the indoor unit, the indoor unit setting may have to be changed. Refer to the instruction manual for each optional accessory. Procedure When in the normal mode, press the “...
  • Page 12: Remote Controller (Wireless Type)

    Remote Controller (Wireless Type) OH08-1 2. Remote Controller (Wireless Type) Unit: mm BRC7C62 / BRC7C67 (for FXC(Q)) 2.1.1 Operation Control Systems...
  • Page 13 OH08-1 Remote Controller (Wireless Type) Control Systems...
  • Page 14 Remote Controller (Wireless Type) OH08-1 Control Systems...
  • Page 15 OH08-1 Remote Controller (Wireless Type) Note 1 : page 17, Note 2 : page 18, Note 3 : page 18, Note 4 : page 17 Control Systems...
  • Page 16 Remote Controller (Wireless Type) OH08-1 Control Systems...
  • Page 17 OH08-1 Remote Controller (Wireless Type) Control Systems...
  • Page 18 Remote Controller (Wireless Type) OH08-1 Note : page 21 Control Systems...
  • Page 19 OH08-1 Remote Controller (Wireless Type) Control Systems...
  • Page 20 Remote Controller (Wireless Type) OH08-1 Control Systems...
  • Page 21 OH08-1 Remote Controller (Wireless Type) Control Systems...
  • Page 22 Remote Controller (Wireless Type) OH08-1 Control Systems...
  • Page 23 OH08-1 Remote Controller (Wireless Type) Control Systems...
  • Page 24 Remote Controller (Wireless Type) OH08-1 2.1.2 Installation Control Systems...
  • Page 25 OH08-1 Remote Controller (Wireless Type) Control Systems...
  • Page 26 Remote Controller (Wireless Type) OH08-1 Control Systems...
  • Page 27 OH08-1 Remote Controller (Wireless Type) Control Systems...
  • Page 28 Remote Controller (Wireless Type) OH08-1 Control Systems...
  • Page 29 OH08-1 Remote Controller (Wireless Type) Control Systems...
  • Page 30 Remote Controller (Wireless Type) OH08-1 BRC7E61W / BRC7E65 (For FXF) 2.2.1 Operation ON OFF DOWN ON OFF TEMP TIME DOWN RESERVE CANCEL TIMER TEST MODE SWING TEST TEST COOL/HEAT CHANGEOVER REMOTE CONTROL SWITCH 3PA63363-24W-0 Control Systems...
  • Page 31 OH08-1 Remote Controller (Wireless Type) Do not stick your fingers or any other 1. SAFETY objects into the air inlet, air outlet or air CONSIDERATIONS direction vanes during operation. The high-speed fan is dangerous and Read the following cautions carefully and could cause injury.
  • Page 32 Remote Controller (Wireless Type) OH08-1 2. NAMES AND FUNCTIONS ON/OFF BUTTON Press the button and the system will OF THE OPERATING SEC- start. Press the button again and the TION (Fig. 1, 2) system will stop. FAN SPEED CONTROL BUTTON DISPLAY “...
  • Page 33 OH08-1 Remote Controller (Wireless Type) OPERATING INDICATOR LAMP (Red) 3. HANDLING FOR This lamp stays lit while the air WIRELESS REMOTE conditioner runs. It flashes when the CONTROLLER unit is in trouble. TIMER INDICATOR LAMP (Green) Precautions in handling remote con- This lamp stays lit while the timer is set.
  • Page 34 Slide from above Pull it upward In this case, contact your DAIKIN dealer. 4. OPERATION RANGE Split System If the temperature or the humidity is beyond the following conditions, safety devices may work and the air conditioner may not operate, or sometimes, water may drop from the indoor unit.
  • Page 35 SPEED. pump type and cooling only type. Contact • This system does not go into operation if your Daikin dealer to confirm your system the room temperature is below 16°C. type. • To protect the unit, turn on the main power ON OFF switch 6 hours before operation.
  • Page 36 Remote Controller (Wireless Type) OH08-1 • Hot air is circulated to warm the room. It FAN OPERATION ....... “ ” will take some time from when the air con- ditioner is first started until the entire room DRY OPERATION ...... “...
  • Page 37 UP AND DOWN DIRECTION cold air directly • The movable limit of the flap is changeable. on the occupants Contact your Daikin dealer for details. of the room.) NOTE • If you try cooling or programmed drying, while the flaps are facing downward, air flow direction may change unexpectedly.
  • Page 38 Remote Controller (Wireless Type) OH08-1 HOW TO SET MASTER PROGRAMMING TIME REMOTE CONTROLLER DOWN (For VRV system) Press the PROGRAMMING TIME but- ton and set the time for stopping or • When the system is installed as shown starting the system.
  • Page 39 OH08-1 Remote Controller (Wireless Type) When the indoor unit with master remote discharge grille on the main unit. When the controller is set to “COOL”, you can switch remote controller does not work, but the over operation mode between “FAN”, “DRY”...
  • Page 40 TROUBLE SPOTS I. EMERGENCY STOP NOTE • Contact your Daikin dealer in case of When the air conditioner stops in emergency, changing the combination or setting of the run lamp on the indoor unit starts group control and two remote controller blinking.
  • Page 41 OH08-1 Remote Controller (Wireless Type) MODE ON OFF TEMP Press OPERATION MODE SELECTOR TIME BUTTON CODE DOWN “ ” on the left-hand of the malfunction code RESERVE CANCEL UNIT N blinks. TIMER MODE SWING DOWN /TEST Press PROGRAMMING TIMER BUTTON and change the malfunction code.
  • Page 42 Remote Controller (Wireless Type) OH08-1 2. The system operates but it does not sufficiently cool or heat. • If the set temperature is not proper. • If the FAN SPEED is set to LOW SPEED. • If the air flow angle is not proper.
  • Page 43 OH08-1 Remote Controller (Wireless Type) 2.2.2 Installation 1. BEFORE INSTALLATION 1-1 ACCESSORIES Check if the following accessories are included with your unit. Wireless remote Remote controller Dry cell battery Unit No. Name Receiver controller holder LR03 (AM4) label Quan- 1 set.
  • Page 44 Remote Controller (Wireless Type) OH08-1 · How to insert the batteries 1. Open the back cover of the remote controller by sliding it in the direction of the arrow. 2. Insert the attached dry cell batteries. Properly insert, set the batteries by matching the (+) and (–) polarity marks as indi-...
  • Page 45: Central Remote Controller

    OH08-1 Remote Controller (Wireless Type) 2. Setting the address of wireless remote controller (It is factory set to “1”) 〈Setting from the remote controller〉 ON OFF 1. Hold down the button and the button /TEST for at least 4 seconds to get the Field Set mode.
  • Page 46: Part 3 Indoor Units

    Remote Controller (Wireless Type) OH08-1 (3) Receiver installation Relay harness 1. Detach the decorative corner panel Stopper diagonally opposite to swing motor. Clamp This corner panel piece is not Swing motor needed hereafter. (For instructions on attaching/ detaching decorative panels, see the installation manual provided with the original panel.)
  • Page 47 OH08-1 Remote Controller (Wireless Type) (Example) If the time to clean air filter is set to “Filter Contamination-Heavy”, set Mode No. to “10”, FIRST CODE NO. to “0”, and SECOND CODE NO. to “02”. FIRST SECOND CODE NO. NOTE) MODE...
  • Page 48: Part 4 Outdoor Units

    Remote Controller (Wireless Type) OH08-1 5. TEST OPERATION Perform test operation according to the instructions in the installation manual attached to the indoor unit. After refrigerant piping, drain piping, and electric wiring, operate according to the table to protect the unit.
  • Page 49: Remote Controller (Wireless Type)

    OH08-1 Remote Controller (Wireless Type) BRC7F634F / BRC7F635F (For FXFQ-P) 2.3.1 Features BRC7F634F (for Heat Pump) BRC7F635F (for Cooling Only) Signal receiver unit can be installed on the panel Signal receiver unit (Installed type) The same operation modes and settings as with wired remote controllers are possible.
  • Page 50: Decoration Panel

    Remote Controller (Wireless Type) OH08-1 2.3.3 Dimensions • REMOTE CONTROLLER DIMENSIONS • RECEIVER INSTALLATION PROCEDURE TRANSMITTING PART RECEIVER REFRIGERANT PIPING SIDE DRAIN PIPING 17.5 SIDE • REMOTE CONTROLLER HOLDER INSTALLATION PROCEDURE <INSTALLATION TO WALL SURFACE> • RECEIVER DETAIL LIQUID CRYSTAL...
  • Page 51 OH08-1 Remote Controller (Wireless Type) 2.3.4 Operation Manual Names and Functions of the Operating Section ON OFF DOWN ON OFF TEMP TIME DOWN RESERVE CANCEL TIMER TEST MODE SWING TEST TEST COOL/HEAT CHANGEOVER REMOTE CONTROL SWITCH Control Systems...
  • Page 52 Remote Controller (Wireless Type) OH08-1 See Fig. 1, 2 DISPLAY “ ” (SIGNAL TRANSMISSION) This lights up when a signal is being transmitted. DISPLAY “ ” “ ” “ ” “ ” “ ” (OPERATION MODE) This display shows the current OPERATION MODE. For cooling only type, “...
  • Page 53 OH08-1 Remote Controller (Wireless Type) FAN/AIR CONDITIONING SELECTOR SWITCH Set the switch to “ ” (FAN) for FAN and “ ” (A/C) for HEAT or COOL. COOL/HEAT CHANGEOVER SWITCH Set the switch to “ ” (COOL) for COOL and “...
  • Page 54 In case the remote controller is not used for a long time take out all batteries in order to prevent liquid leak of the battery. IN THE CASE OF CENTRALIZED CONTROL SYSTEM If the indoor unit is under centralized control, it is necessary to switch the remote controller’s setting. In this case, contact your DAIKIN dealer. Control Systems...
  • Page 55 Operation Procedure Refer to figure 1 on page 49 Operating procedure varies with heat pump type and cooling only type. Contact your Daikin dealer to confirm your system type. To protect the unit, turn on the main power switch 6 hours before operation.
  • Page 56 Remote Controller (Wireless Type) OH08-1 ON OFF ON/OFF Press ON/OFF button. OPERATION lamp lights up or goes off and the system starts or stops OPERATION. NOTE Do not turn OFF power immediately after the unit stops. Then, wait no less than 5 minutes.
  • Page 57 OH08-1 Remote Controller (Wireless Type) Heating capacity & Outdoor air temperature Heating capacity drops as outdoor air temperature lowers. If feeling cold, use another heater at the same time as this air conditioner. Hot air is circulated to warm the room. It will take some time from when the air conditioner is first started until the entire room becomes warm.
  • Page 58 AIR FLOW DIRECTION ADJUST UP AND DOWN DIRECTION The movable limit of the flap is changeable. Contact your Daikin dealer for details. Up and down adjustment Press the AIR FLOW DIRECTION ADJUST button to select the air direction as shown below.
  • Page 59 OH08-1 Remote Controller (Wireless Type) TIMER TIMER MODE START/STOP Press the TIMER MODE START/STOP button several times and select the mode on the display. The display flashes. For setting the timer stop ..“ ” For setting the timer start ..“...
  • Page 60 Remote Controller (Wireless Type) OH08-1 (5) How to Set Master Remote Controller (For VRV System) When the system is installed as shown below, it is necessary to designate the master remote controller. For Heat pump system When one outdoor unit is connected with several indoor units.
  • Page 61 OH08-1 Remote Controller (Wireless Type) MODE Continuously press the OPERATION MODE SELECTOR button for 4 seconds. The displays showing “ ” of all slave indoor unit connected to the same outdoor unit or BS unit flash. MODE Press the OPERATION MODE SELECTOR button to the indoor unit that you wish to designate as the master remote controller.
  • Page 62 Remote Controller (Wireless Type) OH08-1 NOTE Contact your Daikin dealer in case of changing the combination or setting of group control and two remote controller control systems. Not Malfunction of the Air Conditioner The following symptoms do not indicate air conditioner malfunction I.
  • Page 63 OH08-1 Remote Controller (Wireless Type) When the air conditioner stops in emergency, the run lamp on the indoor unit starts blinking. Take the following steps yourself to read the malfunction code that appears on the display. Contact your dealer with this code.
  • Page 64 Remote Controller (Wireless Type) OH08-1 MODE Reset of the display Press OPERATION MODE SELECTOR BUTTON to get the display back to the normal state. ON OFF TEMP TIME CODE DOWN RESERVE CANCEL UNIT N TIMER MODE SWING /TEST II. IN CASE BESIDES EMERGENCY STOP 1.
  • Page 65 OH08-1 Remote Controller (Wireless Type) [Trouble] The RUN lamp of the indoor unit is flashing and the unit does not work at all. Malfunction Code Unit No. which sensed trouble ON OFF TEMP TIME CODE DOWN RESERVE CANCEL UNIT N...
  • Page 66: Fresh Air Intake Kit

    Remote Controller (Wireless Type) OH08-1 2.3.5 Installation Safety Precautions Please read these “SAFETY PRECAUTIONS” carefully before installing air conditioning unit and be sure to install it correctly. After completing installation, conduct a trial operation to check for faults and explain to the customer how to operate the air conditioner and take care of it with the aid of the operation manual.
  • Page 67: Remote Controller (Wireless Type)

    OH08-1 Remote Controller (Wireless Type) Remote Controller Installation NOTES Do not throw the remote controller or impose large shocks. Also, do not store where it may be exposed to moisture or direct sunlight. When operating, point the transmitting part of the remote controller in the direction of the receiver.
  • Page 68 Remote Controller (Wireless Type) OH08-1 (2) Setting the address of wireless remote controller (It is factory set to “ 1 ” ) 〈 〉 Setting from the remote controller ON OFF 1. Hold down the button and the /TEST button for at least 4 seconds to get the Field Set Mode mode.
  • Page 69 OH08-1 Remote Controller (Wireless Type) Installation of the Transmission 1. Remove the lid of the terminal box as described in the Installation Manual supplied with the indoor unit. 2. Fix the transmission at the bottom of the bell mouths on the indoor unit body using provided transmission fixing screws as shown below.
  • Page 70 Remote Controller (Wireless Type) OH08-1 Installation of the Receiver 1. Remove the corner decoration lid of the decoration panel, locating at the opposing corner of the drain piping section. The lid will be no longer in use. Be sure to install the receiver to this corner.
  • Page 71 OH08-1 Remote Controller (Wireless Type) (Example) If the time to clean air filter is set to “Filter Contamination-Heavy”, set Mode No. to “10”, FIRST CODE NO. to “0”, and SECOND CODE NO. to “02”. FIRST SECOND CODE NO. NOTE) MODE...
  • Page 72 Remote Controller (Wireless Type) OH08-1 BRC4C61 / BRC4C62 / BRC4C63 / BRC4C64 (for FXK(Q), FXD(Q), FXDYQ, FXS(Q), FXM, FXMQ-M(A), FXL(Q), FXN(Q), FXYD, FXYB) 2.4.1 Operation 3PA63363-13G-3 Control Systems...
  • Page 73 OH08-1 Remote Controller (Wireless Type) 3PA63363-13G-16 Control Systems...
  • Page 74 Remote Controller (Wireless Type) OH08-1 3PA63363-13G-17 Control Systems...
  • Page 75 OH08-1 Remote Controller (Wireless Type) C: 3PA63363-13G-6 Note 1 : page 77, Note 2 : page 78, Note 3 : page78, Note 4 : page 77 Control Systems...
  • Page 76 Remote Controller (Wireless Type) OH08-1 3PA63363-13G-7 Control Systems...
  • Page 77 OH08-1 Remote Controller (Wireless Type) Control Systems...
  • Page 78 Remote Controller (Wireless Type) OH08-1 Note : page 77 Control Systems...
  • Page 79 OH08-1 Remote Controller (Wireless Type) 3PA63363-13G-10 Control Systems...
  • Page 80 Remote Controller (Wireless Type) OH08-1 3PA63363-13G-11 Control Systems...
  • Page 81 OH08-1 Remote Controller (Wireless Type) 3PA63363-13G-12 Control Systems...
  • Page 82 Remote Controller (Wireless Type) OH08-1 3PA63363-13G-13 Control Systems...
  • Page 83 OH08-1 Remote Controller (Wireless Type) 3PA63363-13G-14 Control Systems...
  • Page 84 Remote Controller (Wireless Type) OH08-1 2.4.2 Installation 2P018568 Control Systems...
  • Page 85 OH08-1 Remote Controller (Wireless Type) 2P018568 Control Systems...
  • Page 86 Remote Controller (Wireless Type) OH08-1 2P018568 Control Systems...
  • Page 87 OH08-1 Remote Controller (Wireless Type) 2P018568 Control Systems...
  • Page 88: Brc4C65 / Brc4C66 (For Fxmq-P)

    Remote Controller (Wireless Type) OH08-1 BRC4C65 / BRC4C66 (for FXMQ-P) 2.5.1 Features BRC4C65 (for Heat Pump) BRC4C66 (for Cooling Only) Signal receiver unit The same operation modes and settings as with wired remote controllers are possible. A compact and light signal receiver unit to be mounted into a wall or ceiling is included.
  • Page 89 OH08-1 Remote Controller (Wireless Type) 2.5.3 Dimensions • REMOTE CONTROLLER DIMENSIONS • RECEIVER DETAIL TRANSMITTING PART Switch box (Field Supplied parts) 17.5 2-5 × 9 Slot • REMOTE CONTROLLER HOLDER INSTALLATION PROCEDURE < INSTALLATION TO WALL SURFACE > P1 P2...
  • Page 90 Remote Controller (Wireless Type) OH08-1 2.5.4 Operation Manual Names and Functions of the Operating Section ON OFF DOWN ON OFF TEMP TIME DOWN RESERVE CANCEL TIMER TEST MODE TEST TEST COOL/HEAT CHANGEOVER REMOTE CONTROL SWITCH Control Systems...
  • Page 91 OH08-1 Remote Controller (Wireless Type) See Fig. 1, 2 DISPLAY “ ” (SIGNAL TRANSMISSION) This lights up when a signal is being transmitted. DISPLAY “ ” “ ” “ ” “ ” “ ” (OPERATION MODE) This display shows the current OPERATION MODE. For straight cooling type, “...
  • Page 92 Remote Controller (Wireless Type) OH08-1 AIR FILTER CLEANING TIME INDICATOR LAMP (Red) Lights up when it is time to clean the air filter. DEFROST LAMP (Orange) Lights up when the defrosting operation has started. (For straight cooling type this lamp does not turn on.) FAN/AIR CONDITIONING SELECTOR SWITCH Set the switch to “...
  • Page 93 OH08-1 Remote Controller (Wireless Type) ON OFF ON OFF TEMP DOWN TIME DOWN RESERVE CANCEL TIMER MODE /TEST ON OFF ON OFF TEMP DOWN TIME DOWN RESERVE CANCEL TIMER MODE /TEST Control Systems...
  • Page 94 Remote Controller (Wireless Type) OH08-1 ON OFF ON OFF TEMP TEMP TIME TIME DOWN DOWN RESERVE CANCEL RESERVE CANCEL TIMER TIMER MODE MODE /TEST /TEST ON OFF ON OFF TEMP TEMP TIME TIME CODE DOWN DOWN RESERVE CANCEL RESERVE CANCEL...
  • Page 95 OH08-1 Remote Controller (Wireless Type) Handling for Wireless Remote Controller Precautions in handling remote controller Direct the transmitting part of the remote controller to the receiving part of the air conditioner. If something blocks the transmitting and receiving path of the indoor unit and the remote controller as curtains, it will not operate.
  • Page 96 DAIKIN dealer. Operation Procedure Operating procedure varies with heat pump type and straight cooling only type. Contact your Daikin dealer to confirm your system types. To protect the unit, turn on the main power switch 6 hours before operation.
  • Page 97 OH08-1 Remote Controller (Wireless Type) Press ON/OFF button. OPERATION lamp lights up and the system starts OPERATION. ADJUSTMENT For programming TEMPERATURE and FAN SPEED and AIR FLOW DIRECTION, follow the procedure shown below. Press TEMPERATURE SETTING button and program the setting temperature.
  • Page 98 Remote Controller (Wireless Type) OH08-1 Heating capacity & Outdoor air temperature Heating capacity drops as outdoor air temperature lowers. If feeling cold, use another heater at the same time as this air conditioner. Hot air is circulated to warm the room. It will take some time from when the air conditioner is first started until the entire room becomes warm.
  • Page 99 OH08-1 Remote Controller (Wireless Type) PROGRAM TIMER OPERATION (Fig. 7) The timer is operated in the following two ways. Programming the stop time ( ..The system stops operating after the set time has elapsed. Programming the start time ( ..The system starts operating after the set time has elapsed.
  • Page 100 Remote Controller (Wireless Type) OH08-1 〈〈 〉〉 For Heat pump system When one outdoor unit is connected with several indoor units. Outdoor unit Indoor unit One of these remote controllers needs to be designated as the master remote controller. 〈〈...
  • Page 101 Under two remote controller control system, wireless remote controller cannot control timer operation. Only the operating indicator lamp out of 3 other lamps on the indoor unit display functions. Contact your Daikin dealer in case of changing the combination or setting of group control and two remote controller control systems.
  • Page 102 Remote Controller (Wireless Type) OH08-1 Not Malfunction of the Air Conditioner The following symptoms do not indicate air conditioner malfunction I. THE SYSTEM DOES NOT OPERATE The system does not restart immediately after the ON/OFF button is pressed. If the OPERATION lamp lights, the system is in normal condition. It does not restart immediately because a safety device operates to prevent overload of the system.
  • Page 103 OH08-1 Remote Controller (Wireless Type) II. IN CASE BESIDES EMERGENCY STOP 1. The unit does not operate at all. Check if the receiver is exposed of sunlight or strong light. Keep receiver away from light. Check if there are batteries in the remote controller. Place the batteries.
  • Page 104 Remote Controller (Wireless Type) OH08-1 2.5.5 Installation Caution Do not install more than 3 receivers in the vicinity of one another. With 4 or more units, there is always the possibility of malfunction. Remove the Upper Part of Receiver Insert the screwdriver here and gently work off the upper part of the receiver.
  • Page 105: Central Remote Controller

    OH08-1 Remote Controller (Wireless Type) SAFETY CONSIDERATIONS Please read this "SAFETY CONSIDERATIONS" carefully before installing air conditioning equipment and be sure to install it correctly. After completing the installation, make sure at start up operation that the unit operates properly. Please instruct the customer how to operate the unit and keep maintenance.
  • Page 106 Remote Controller (Wireless Type) OH08-1 Insert the lower part into the opening in the ceiling, first by pressing the wings inward to fit the hole and then by pushing from the screws until it sits flat on the ceiling. Tighten the screws until the lower part is fixed in place.
  • Page 107 OH08-1 Remote Controller (Wireless Type) (2) Fix the Lower Part Install the lower part on theh switch box (field supplied part) Select as flat a place ash possible to install the lower part. Also, be aware of the fact that overtightening the screws (attached) may deform the case and possibly make it harder to install the upper part.
  • Page 108 Remote Controller (Wireless Type) OH08-1 BRC7E63W / BRC7E66 (for FXH(Q)) 2.6.1 Operation ON OFF DOWN ON OFF TEMP TIME DOWN RESERVE CANCEL TIMER TEST MODE SWING TEST TEST COOL/HEAT CHANGEOVER REMOTE CONTROL SWITCH 21 20 3PA63363-21T-0 Control Systems...
  • Page 109 OH08-1 Remote Controller (Wireless Type) TEMPERATURE SETTING BUTTON NAMES AND FUNCTIONS Use this button for SETTING TEMPER- OF THE OPERATING SEC- ATURE (Operates with the front cover TION (Fig. 1, 2) of the remote controller closed.) PROGRAMMING TIMER BUTTON DISPLAY “...
  • Page 110 Remote Controller (Wireless Type) OH08-1 AIR FILTER CLEANING TIME HANDLING FOR INDICATOR LAMP (Red) WIRELESS REMOTE Lights up when it is time to clean the air CONTROLLER filter. DEFROST LAMP (Orange) Precautions in handling remote con- Lights up when the defrosting opera- troller tion has started.
  • Page 111 Pull it upward If the indoor unit is under centralized control, it is necessary to switch the remote controller’s setting. In this case, contact your DAIKIN dealer. OPERATION PROCEDURE Refer to figure 1 ( Note ) Remote • Operating procedure varies with heat controller pump type and cooling only type.
  • Page 112 Remote Controller (Wireless Type) OH08-1 〈〈 〈〈 〈〈 〈〈FOR SYSTEMS WITHOUT COOL/ OPERATION MODE HEAT CHANGEOVER REMOTE SELECTOR CONTROL SWITCH〉〉 〉〉 〉〉 〉〉 (1) Select OPERATION MODE with the Refer to figure 1-1, 2 ( Note ) COOL/HEAT CHANGEOVER REMOTE OPERATION MODE CONTROL SWITCH as follows.
  • Page 113 OH08-1 Remote Controller (Wireless Type) • As the frost on the coil of an outdoor unit In case of automatic operation increase, heating effect decreases and the Each time this button is pressed, system goes into DEFROST OPERATION. setting temperature shifts to “H”...
  • Page 114 A. UP AND DOWN DIRECTION on parts in the air discharge outlet from dripping. • The movable limit of the flap is change- able. Contact your Daikin dealer for • Operation mode includes automatic details. operation. Press the AIR FLOW DIRECTION B.
  • Page 115 OH08-1 Remote Controller (Wireless Type) HOW TO SET MASTER PROGRAMMING TIME REMOTE CONTROLLER DOWN (For VRV system ) Press the PROGRAMMING TIME button and set the time for stopping • When the system is installed as shown or starting the system.
  • Page 116 Remote Controller (Wireless Type) OH08-1 When the indoor unit with master remote EMERGENCY OPERATION controller is set to “COOL” , you can switch over operation mode between “FAN”, “DRY” When the remote controller does not work and “COOL” . due to battery failure or the absence thereof,...
  • Page 117: How To Diagnose Trouble Spots

    • Only the operating indicator lamp out of 3 other lamps on the indoor unit display functions. NOTE HOW TO DIAGNOSE • Contact your Daikin dealer in case of changing the combination or setting of TROUBLE SPOTS group control and two remote controller control systems.
  • Page 118 Remote Controller (Wireless Type) OH08-1 Press until the indoor unit makes a long beep. DOWN The malfunction code is fixed when the indoor unit makes a long beep. Press PROGRAMMING TIMER BUTTON and change the unit number. MODE Reset of the display...
  • Page 119 OH08-1 Remote Controller (Wireless Type) Trouble] The RUN lamp of the indoor unit is flashing and the unit does not work at all. Malfunction Code Unit No. which sensed trouble ON OFF Number TEMP TIME CODE DOWN Operate the indoor unit with the remote con-...
  • Page 120 Remote Controller (Wireless Type) OH08-1 2.6.2 Installation 1P067740-1B Control Systems...
  • Page 121 OH08-1 Remote Controller (Wireless Type) 1P067740-1B Control Systems...
  • Page 122 Remote Controller (Wireless Type) OH08-1 BRC7E618 / BRC7E619 (for FXA(Q)) 2.7.1 Operation ON OFF DOWN ON OFF TEMP TIME DOWN RESERVE CANCEL TIMER TEST MODE SWING TEST TEST COOL/HEAT CHANGEOVER REMOTE CONTROL SWITCH 3PA63363-25Z-0 Control Systems...
  • Page 123 OH08-1 Remote Controller (Wireless Type) Do not stick your fingers or any other 1. SAFETY objects into the air inlet, air outlet or air CONSIDERATIONS direction vanes during operation. The high-speed fan is dangerous and Read the following cautions carefully and could cause injury.
  • Page 124 Remote Controller (Wireless Type) OH08-1 2. NAMES AND FUNCTIONS TEST DISPLAY “ ” OF THE OPERATING SEC- (INSPECTION/ TEST OPERATION) When the INSPECTION/TEST OPER- TION (Fig. 1, 2) ATION BUTTON is pressed, the display shows the system mode is in.
  • Page 125 OH08-1 Remote Controller (Wireless Type) RECEIVER 3. HANDLING FOR This receives the signals from the WIRELESS REMOTE remote controller. CONTROLLER OPERATING INDICATOR LAMP (Red) This lamp stays lit while the air Precautions in handling remote con- conditioner runs. It flashes when the troller unit is in trouble.
  • Page 126 If the indoor unit is under centralized control, it is controller remote controller necessary to switch the remote controller’s setting. Slide from above Pull it upward In this case, contact your DAIKIN dealer. 4. OPERATION RANGE VRV System See the operation manual provided with the air conditioner. Remote 5.
  • Page 127 OH08-1 Remote Controller (Wireless Type) 〈〈 〈〈 〈〈 〈〈FOR SYSTEMS WITHOUT COOL/ 〈〈 〈〈 〈〈 〈〈FOR SYSTEMS WITH COOL/HEAT HEAT CHANGEOVER REMOTE CHANGEOVER REMOTE CONTROL CONTROL SWITCH〉〉 〉〉 〉〉 〉〉 SWITCH〉〉 〉〉 〉〉 〉〉 Refer to figure 1-1, 2 (Note 1)
  • Page 128 Remote Controller (Wireless Type) OH08-1 [Explanation of heating operation] Defrost operation • As the frost on the coil of an outdoor unit In case of automatic operation increase, heating effect decreases and the Each time this button is pressed, system goes into DEFROST OPERATION.
  • Page 129 OH08-1 Remote Controller (Wireless Type) Adjusting left / right air flow direction Programming the start time ( Angle the flaps to the left/ ..The system starts right from the knob, as operating after the set time has elapsed. wanted or as needed to air The timer can be programmed a maximum condition the room.
  • Page 130 Remote Controller (Wireless Type) OH08-1 For example. For Heat recovery system When one BS unit is connected with several When the timer is indoor units. ON OFF programmed to stop the system after 3 TEMP TIME hours and start the...
  • Page 131 The system operates with the previously set air flow direction. functions. NOTE • Contact your Daikin dealer in case of changing the combination or setting of group control and two remote controller control systems. 3PA63363-25Y-9...
  • Page 132 Remote Controller (Wireless Type) OH08-1 6. NOT MALFUNCTION OF TEST THE AIR CONDITIONER Press the INSPECTION/TEST button The following symptoms do not indi- to select the inspection mode “ ”. cate air conditioner malfunction “ ” appears on display and blinks. “UNIT”...
  • Page 133 OH08-1 Remote Controller (Wireless Type) Press OPERATION MODE SELECTOR Check if the indoor unit number and BUTTON wireless remote controller number are equal. “ ” on the right-hand of the malfunction code blinks. DOWN Press PROGRAMMING TIMER BUTTON and change the malfunction code.
  • Page 134 Remote Controller (Wireless Type) OH08-1 Trouble] The RUN lamp of the indoor unit is flashing and the unit does not work at all. Malfunction Code Unit No. which sensed trouble ON OFF TEMP TIME CODE DOWN RESERVE CANCEL UNIT N...
  • Page 135 OH08-1 Remote Controller (Wireless Type) 2.7.2 Installation 1. BEFORE INSTALLATION 1-1 ACCESSORIES Check if the following accessories are included with your unit. Receiver Wireless (3) Relay (4) Relay Name remote Screw (1) Light receiver (2) Transmission harness - long harness - short...
  • Page 136 Remote Controller (Wireless Type) OH08-1 Installing to a wall or a pillar 1. Fix the remote controller holder with the screws. 2. Slide the remote controller into the remote controller holder from the top. How to insert the batteries 1. Open the back cover of the remote controller by sliding it in the Back cover direction of the arrow.
  • Page 137 OH08-1 Remote Controller (Wireless Type) 2. Setting the address of wireless remote controller (It is factory set to “1”) 〈Setting from the remote controller〉 ON OFF 1. Hold down the button and the button /TEST for at least 4 seconds to get the Field Set mode.
  • Page 138 Remote Controller (Wireless Type) OH08-1 (3) Attaching the receiver 1. Connect the included relay harness – long (3) and relay harness – short (4) relay harnesses to the connector on the transmission PC-board (2). Connect firmly to Transmission PC-board (2) CN1/X1A the connector.
  • Page 139 OH08-1 Remote Controller (Wireless Type) 4. Connect the relay harnesses which were connected to the transmission PC-board (2) in step 1. as follows. Relay harness – long (3) to connector X24A on the indoor unit PC-board Relay harness – short (4) to connector CN1/X1A on the light receiver assembly (1) After making these connection, clamp down relay harness –...
  • Page 140: Test Operation

    Remote Controller (Wireless Type) OH08-1 4. FIELD SETTING MODE NO. If optional accessories are mounted on the indoor unit, the indoor FIELD SET MODE unit setting may have to be changed. Refer to the instruction man- ON OFF ual (optional hand book) for each optional accessory.
  • Page 141 OH08-1 Remote Controller (Wireless Type) BRC7E530W / BRC7E531W (for FXZQ) 2.8.1 Operation 3P107422-1F Control Systems...
  • Page 142 Remote Controller (Wireless Type) OH08-1 3P107422-1F Control Systems...
  • Page 143 OH08-1 Remote Controller (Wireless Type) C:3P107422-1F Note1 : page 146, Note2 : page 147 Control Systems...
  • Page 144 Remote Controller (Wireless Type) OH08-1 • • • • • • 3P107422-1F Control Systems...
  • Page 145 OH08-1 Remote Controller (Wireless Type) • • 3P107422-1F Control Systems...
  • Page 146 Remote Controller (Wireless Type) OH08-1 3P107422-1F Note : page 139 Control Systems...
  • Page 147 OH08-1 Remote Controller (Wireless Type) • • 3P107422-1F Control Systems...
  • Page 148 Remote Controller (Wireless Type) OH08-1 • • • 3P107422-1F Control Systems...
  • Page 149 OH08-1 Remote Controller (Wireless Type) • 3P107422-1F Control Systems...
  • Page 150 Remote Controller (Wireless Type) OH08-1 3P107422-1F Control Systems...

Table of Contents