[B21] AUTO ADJUST menu
This menu is displayed when AUDO ADJUST is selected
in the [B2] AUTO... menu.
The following message appears.
SET PROBE ON CURSOR
Attach the probe on the center of the CRT to start automatic
adjustment. (It may take some time to adjust
automatically.)
To cancel/stop the adjustment
Press the MENU button.
[B3] COPY FROM... menu
Copy other matrix data.
PRESET VALUE...: Copy other data in this monitor.
k[B31]
OTHER MONITOR...: Copy data from another
monitor. k[B32]
MEMORY STICK...: Copy data from a file in the
"Memory Stick". k[B33]
[B31] PRESET VALUE... menu
Select the data to be copied.
Select one from among D93, D65, D61, USER1, USER2,
USER3, USER4 and USER5.
D93: Copy the color temperature of D93.
D65: Copy the color temperature of D65.
D61: Copy the color temperature of D61.
USER1 to 5: Copy the color temperature of USER1 to
5.
When D93, D65 or D61 data is changed, they are displayed
as D93*, D65* or D61*.
[B32] OTHER MONITOR... menu
Assign the ID No. of the source monitor.
MONITOR ID...: Enter the ID No. of the monitor.
k[B321]
When the NETWORK switch is set to PEER TO PEER,
this is not selectable.
[B321] OTHER MONITOR... menu
Select the data from another selected monitor.
Select one from among D93, D65, D61, USER1, USER2,
USER3, USER4 and USER5.
D93: Copy the color temperature of D93.
D65: Copy the color temperature of D65.
D61: Copy the color temperature of D61.
USER1 to 5: Copy the color temperature of USER1 to
5.
When D93, D65 or D61 data is changed, they are displayed
as D93*, D65* or D61*.
[B33] MEMORY STICK... menu
Select the file in the source "Memory Stick". k[B331]
36
[B] Adjusting the Color Temperature – COLOR TEMP ADJ Menu
[B331] MEMORY STICK menu
Select the data from a file in the "Memory Stick"
Select one from among D93, D65, D61, USER1, USER2,
USER3, USER4 and USER5.
D93: Copy the color temperature of D93.
D65: Copy the color temperature of D65.
D61: Copy the color temperature of D61.
USER1 to 5: Copy the color temperature of USER1 to
5.
When D93, D65 or D61 data is changed, they are displayed
as D93*, D65* or D61*.
[B4] RESTORE FACTORY DATA menu
Reset the color temperature to the default setting.
You cannot select this when USER1 to 5 is selected or the
setting is the default value. The following message appears
to confirm the data reset operation.
RESTORE FACTORY DATA?
OK: Press the ENTER or Ent button to reset the data.
CANCEL: Press the MENU button to cancel the reset
operation.
[B5] ANALYZE menu
Perform operation according to the message to enable the
BKM-14L to read the color system and luminance value.
SET PROBE ON CURSOR
Attach the probe on the center of the CRT.
Once the probe has carried out calibration, it can start to
analyze the monitor's performance.
To cancel the analysis
Press the MENU button.
Notes
• Do not cut the R, G, or B beam or display the marker
before carrying out calibration of BKM-14L. It may
cause non-detection of BKM-14L.
• During analyzing, do not disconnect BKM-14L from the
OPTION connector. If nothing has been displayed on the
monitor, press the MENU button. The display returns to
the COLOR TEMP ADJ menu.