To cancel the adjustment
Press the MENU button. The adjusted data is cleared and
the screen returns to [E21]. (It may take some time to
change to the previous menu.)
When you want to erase characters from the
screen while adjusting the convergence
Press the CHAR OFF button. The characters disappear. To
display characters, press the CHAR OFF button again.
[E3] DIGITAL UNIFORMITY ADJ... menu
Adjust the color unevenness of the CRT.
The signal system, aspect and scan size for the adjustment
are displayed on the top of the screen.
MANUAL...: Adjust with the MANUAL knobs.
k[E31]
AUTO FULL POINTS ADJ: Automatically adjust
the whole area of the screen in sequence using the
Sony BKM-14L Auto Setup Probe. k[E32]
AUTO ONE POINT ADJ: Automatically adjust only
the selected adjustment point of the screen using the
Sony BKM-14L Auto Setup Probe. k[E33]
SIGNAL: Select the white signal to be used for
adjustment (default setting is EXT).
EXT: Use an external input signal. Input the
appropriate signal.
INT: Use an internal white signal.
RESTORE FACTORY DATA: Reset the DIGITAL
UNIFORMITY data of the monitored signal
system, aspect and scan size to the default setting.
The following message appears to confirm the data
reset operation.
RESTORE FACTORY DATA?
OK: Press the ENTER or Ent button to reset the
data.
CANCEL: Press the MENU button to cancel the
reset operation.
[E31] MANUAL... menu
Adjust the gain of R, G and B with the MANUAL knobs.
MANUAL ADJUST: Adjust the gain. k[E311] (It
may take some time to display the next menu.)
CURSOR H SIZE: Specify the horizontal size of the
cursor (1 to 5).
V SIZE: Specify the vertical size of the cursor (1 to 5).
Knobs and buttons used for each adjustment
RED: CONTRAST KNOB (Adjust the R gain with
the CONTRAST knob.)
GREEN: BRIGHT KNOB (Adjust the G gain with
the BRIGHT knob.)
BLUE: CHROMA KNOB (Adjust the B gain with
the CHROMA knob.)
CURSOR POSITION: 10KEY (Move the cursor
using the numeric keypad (except the 5 button) as
illustrated below. Turn the cursor ON/OFF using
the 5 button.)
Page 50