485 Termination; Function - Veilux IR PTZ VP-60IR Series User Manual

Table of Contents

Advertisement

DIP Switch Setting
B. 485 TERMINATION
The 1st of DIP SW2 is used for 100Ω termination.
Set ON DIP SW2 -1st of only the last looped camera from the controller.
Even in case of only one camera, set ON DIP SW2 -1st of the camera.
C. FUNCTION
DIP S/W NO.
1
Binary Number Protocol #1
2
Binary Number Protocol #2
3
Binary Number Protocol #3
4
Binary Number Baud rate #1
5
Binary Number Baud rate #2
6
7
8
CAM 1
CAM 2C
DEFINITION
Reserved
Reserved
Termination
037
AM n-1
DETAIL
321 : Dip S/W Number
000 : PELCO-D/P
010 : SAMSUNG
100 : x
110 : x
54 : Dip S/W Number
00 : x
10 : 4800 bps
Reserved
Reserved
RS-485 terminating resistance can be used
by user.
ON : Available
PTZ CAMERA
TERMINATION
SW1-ON
CAM n
001 : VICON
011 : SAE
101 : x
111 : x
01 : 2400 bps
11 : 9600 bps
OFF : Not Available.