Diagnostic

Whenever the dome is powered on, a standard diagnostic is operated.
CAMERA ID
BAUD RATE
WAITING............
A. Pan Origin Test
Zero point of Pan is located during the Panning test.
B. Tilt Origin Test
Zero point of Tilt is located during the Tilt test.
C. TX connection Test
Wait for 60 seconds for TX Connection Test,
During 60 seconds, the camera is must received a signal by any control
equipment
as DVR or controller.
Then Ok is displayed then automatically verifying TX Connection Test.
* If "Not Tested" is displayed in the test,
- The result which is not received any signal from DVR or controller
- Wrong connecting way such as the protocol, baud rate or RS-485
connection.
The use may check the install way carefully.
D. Camera Comm. Test
Camera communication is also checked.
OK should be displayed in these four tests before installation.
If all the above Tests are OK , "NO W EEPROM CHECKING" and "ALL DATA
INITIALIZING" is displayed and the camera is ready to operate.
: 001
: 2400BPS
011
PAN ORIGIN
TEST OK
TILT ORIGIN
TEST OK
TX CONNECTION
TEST OK
CAMERA COMM
TEST OK
PTZ CAMERA