OSD Menu Setting
G. TOUR
You can use this function using Left/Right of Joystick after choice the TOUR in
the Main Menu.
G-1. TOUR NO.
This is for Menu for choice the GROUP NUMBER of TOUR that you'll set it up
into GROUP out of 8 of TOUR. Possibly choice 1~8.
G-2. TOUR TITLE
ID for tour can be registered as option by user within range of 16words.
- Default is for ""TOUR**"". (* is for TOUR NUMBER)
- You can change the character with PAN LEFT/RIGHT and position with
ZOOM IN/OUT.
- For make ID changing over, move to OSD MENU by controlling TILT.
G-3. TOUR STEP
This is for turn of playback of CALL you'll design the GROUP. Possibly it
could be registered 60 in maximum and CALL will working as turn.
G-4. CALL NO.
This is for registration the CALL to TOUR STEP.
- Choose the CALL number using LEFT/RIGHT of Joystick.
- You can input it directly using [1..64],[100,255]+ CALL.
- The color for CALL should be changed in case that CALL is registered. G-5.
DWELL TIME
This is for setting the holding time after moving is finished to relevant

CALL.

- The value for setting is 1~99, you can input it directly using [1-99]+CALL.
TOUR SET
TOUR NO.
: 01
TOUR TITLE

: TOUR01

TOUR STEP
: 01
CALL NO.
: 001
DWELL TIME
: 03
SPEED
: 300º/S
SAVE
EXIT