Veilux Model # VP-58CND12X User Manual
MINI SPEED DOME CAMERA
12X Mini Speed Dome Camera

Instruction Manual

Website:
www.Veilux.net
Phone # 1-800-510-6528

Advertisement

Table of Contents
loading

Summary of Contents for Veilux VP-58CND12X

  • Page 1: Instruction Manual

    Veilux Model # VP-58CND12X User Manual MINI SPEED DOME CAMERA 12X Mini Speed Dome Camera Instruction Manual Website: www.Veilux.net Phone # 1-800-510-6528...
  • Page 2: Table Of Contents

    Veilux Model # VP-58CND12X User Manual CONTENTS Warnings & Caution ---------------------------------------------------------------------------------------- 3 What’s in the Box? ----------------------------------------------------------------------------------------- 3 General Features --------------------------------------------------------------------------------------------- 4 Names of Each Part ---------------------------------------------------------------------------------------- 5 Installation ---------------------------------------------------------------------------------------------------- 6 A. Connections ---------------------------------------------------------------------------------- 6 B. Ceiling Mount Type ------------------------------------------------------------------------ 7 C.
  • Page 3: Warnings & Caution

    Veilux Model # VP-58CND12X User Manual WARNINGS & CAUTION If you fail to read this information and handle the product incorrectly, death or serious injury may occur. The unit should be installed by the trained personnel Switch off immediately if the product emits smoke or abnormal heat.
  • Page 4: General Features

    Veilux Model # VP-58CND12X User Manual GENERAL FEATURES 12X Zoom Mini Speed Dome Quick Operation Keys This camera provides quick function keys to allow 12X Optical Zoom with 16X digital zoom control by most keyboards and DVRs that have Pelco protocol support.
  • Page 5: Names Of Each Part

    Veilux Model # VP-58CND12X User Manual NAMES OF EACH PART FIG. 1 1. Surface Mount Adaptor 2. Cap Screw (PT3/4, 1EA) 3. Dip Switch 4. Terminal Block 5. Main body Website: www.Veilux.net Phone # 1-800-510-6528...
  • Page 6: Installation

    Veilux Model # VP-58CND12X User Manual INSTALLATION A. CONNECTIONS 1. Loose the screws on the domes cover and remove it from the base. (Screws won’t be removed) 2. Loosen the screws which connect mount cover and Main base and separate dome cover from the main base.
  • Page 7: Ceiling Mount Type

    Veilux Model # VP-58CND12X User Manual INSTALLATION B. CEILING MOUNT TYPE FIG. 4 FIG. 3 1. Fix the surface mount adaptor with 4pcs of screws on the place where you want to install. (FIG. 3) Caution ) Be sure to use seal tape for 3/4” cap screw to prevent a water leakage.
  • Page 8: Embedded Mount Type

    Veilux Model # VP-58CND12X User Manual INSTALLATION C. EMBEDDED MOUNT TYPE Contents ■ Embedded mount bracket 1ea ■ Holder 3ea ■ Decoration cover 1ea ■ Safety wire 2ea ■ Screw – M3.0 x 6 5ea ■ Screw - Ø4.0 x 16 1ea...
  • Page 9 Veilux Model # VP-58CND12X User Manual INSTALLATION Make a hole, 190mm, on the ceiling. (FIG. 6) Hook the safety wire over suspension and safety wire hold of embedded mount bracket. Fold the lock levers and insert the bracket into the hole.
  • Page 10: Pipe Mount Type

    Veilux Model # VP-58CND12X User Manual INSTALLATION D. PIPE MOUNT TYPE Contents ■ Pipe mount bracket 1ea ■ Rubber 1ea ■ Screw – M4.0 x 8 4ea ■ Set anchor bolt (W5/16) 4ea SCREW M4x8 (4ea) BRACKET (RUBBER BOTTOM VIEW)
  • Page 11 Veilux Model # VP-58CND12X User Manual INSTALLATION 3. If you want to install the speed dome on the concrete wall, you need to make 12.5mm diameter 4 holes by drill like FIG. 13 (Depth 37mm) 4. Install SET ANCHOR BOLT on the holes.
  • Page 12: Gooseneck Mount Type

    Veilux Model # VP-58CND12X User Manual INSTALLATION E. GOOSENECK MOUNT TYPE ■ Contents Rub b er 1 e a ■ ■ Gooseneck mount bracket 1ea S cr ew M 4 x 8 4 e a ■ Set anchor bolt (W5/16) 4ea <the cable into the ceiling>...
  • Page 13: Wall Mount Type

    Veilux Model # VP-58CND12X User Manual INSTALLATION F. WALL MOUNT TYPE Contents ■ Wall mount bracket 1ea ■ Set Anchor Bolt (W5/16) 4ea ■ Hexagon Socket head cap screw M4.0 x16 4ea ■ Hexagon wrench 3mm L Type 1ea If you want to install the speed dome on the concrete wall, you need to make 12.5mm diameter 4 holes by drill like FIG.
  • Page 14 Veilux Model # VP-58CND12X User Manual INSTALLATION Assemble a wall mount bracket and camera by Hexagon socket head cap screws (M4.0X16) (FIG. 20) HEXAGON SOCKET HEAD CAP SCREW M4.0x16 4EA FIG. 20 Website: www.Veilux.net Phone # 1-800-510-6528...
  • Page 15: Corner Mount Type

    Veilux Model # VP-58CND12X User Manual INSTALLATION G. CORNER MOUNT TYPE Contents ■ Corner mount adaptor 1ea ■ Set Anchor Bolt (W5/16) 4ea ■ M10 Bolt & Nut 4ea First mark the positions of holes placing the corner mount bracket. (FIG. 21) Make 12.5mm diameter 4 holes by drill.
  • Page 16 Veilux Model # VP-58CND12X User Manual INSTALLATION After driving a bottom cover assembly to gooseneck mount bracket, as shown on FIG 23, assemble mini PTZ with bottom cover assembly. (FIG. 24) Caution ) Be sure to use seal tape for pipe screw to prevent a water leakage.
  • Page 17: Pole Mount Type

    Veilux Model # VP-58CND12X User Manual INSTALLATION H. POLE MOUNT TYPE Contents ■ Pole mount adaptor 1ea ■ Band Clamp 2ea ■ M10 Bolt & Nut 4ea Fix the wanted bracket on the pole mount bracket with 4 ea of M10 BOLT before you install the pole mount bracket.
  • Page 18: Quick Operating Keys

    Veilux Model # VP-58CND12X User Manual QUICK OPERATING KEYS The dome supports Pelco-D/P, SAMSUNG and VICON protocols. The dome may be used with any controller or DVR etc that supports the Pelco D and Pelco P protocols. The default setting of the dome is Pelco D / P with 2400 bps (baud rate).
  • Page 19: Vicon Protocol

    Veilux Model # VP-58CND12X User Manual QUICK OPERATING KEYS [VICON PROTOCOL] If user wants to choose Vicon Protocol, the user may change the dip switch first. (Refer to Page #36 DIP SWITCH SETTING - PROTOCOL) Baud Rate: 4800 (Vicon default) The operation system is almost same as Pelco D/P protocols but some special features are different way as noted below’...
  • Page 20: Diagnostic

    Veilux Model # VP-58CND12X User Manual DIAGNOSTIC Whenever the dome is powered on, a standard diagnostic is operated. The following messages are displayed on the monitor. CAMERA ID : 001 BAUD RATE : 2400 BPS WAITING……… PAN ORIGIN TEST TILT ORIGIN...
  • Page 21: Osd Menu Setting

    Veilux Model # VP-58CND12X User Manual OSD ME NU S ETTING A. OSD MENU TABLE Website: www.Veilux.net Phone # 1-800-510-6528...
  • Page 22: Dome Set

    Veilux Model # VP-58CND12X User Manual OSD MENU SETTING To enter OSD Menu, press the button 95 + PRESET. MAIN MENU DOME SETUP CAMERA PRESET AUTO SCAN TOUR PRIVICY PATTERN ALARM SECTOR EXIT * Use “ up down” to move the position and “ left right” to make selection B.
  • Page 23 Veilux Model # VP-58CND12X User Manual OSD MENU SETTING B-2. DOME SET - RECOVER This feature allows the dome to revert to a specific programmed action when the dome has not received a command for the recovery timer period. Actions can be Auto scan, group tour and pattern. The recovery time can be programmed from 15 second to 90 seconds.
  • Page 24 Veilux Model # VP-58CND12X User Manual OSD MENU SETTING B-8-2. DOME SET - [NEXT PAGE] - [PASSWORD] To enter this page to set a password, move joystick or pan key in the right direction. The password must be set by preset number from 001 to 255 (Default 99)
  • Page 25 Veilux Model # VP-58CND12X User Manual OSD MENU SETTING B-8-4. DOME SET - [NEXT PAGE] - [SYSTEM STATUS] This page shows the information of this camera. SYSTEM STATUS PROTOCOL : PELCO D, P BAUD RATE : 2400 BPS FIRMWARE VER. : X.XX DEFAULT SETTING UPGRADED DATE : YY.MM.DD...
  • Page 26 Veilux Model # VP-58CND12X User Manual OSD MENU SETTING Press FOCUS NEAR button when the cursor is at YES in order to clear memorized data. Then each item such as tour, preset, and sector will flicker for about 2~3 seconds. After this process, the menu is returned to the previous page.
  • Page 27: Camera Set

    Veilux Model # VP-58CND12X User Manual OSD MENU SETTING C. CAMERA SET CAMERA SET FLICKER MIRROR APERTURE : 10 D ZOOM : OFF DEFAULT SETTING WB MODE : AWB MODE PIC FLIP : OFF : OFF D/N MODE : AUTO...
  • Page 28 Veilux Model # VP-58CND12X User Manual OSD MENU SETTING C-6. CAMERA SET - PIC FLIP The picture flip feature swps the top and bottom of the image, literally inverting it. The default setting is OFF. C-7. CAMERA SET - BLC (Back Light Compensation) The default setting is OFF and BLC modes can be OFF/ON.
  • Page 29: Preset

    Veilux Model # VP-58CND12X User Manual OSD MENU SETTING D. PRESET SET To enter PRESET SET, move joystick to the right direction. PRESET SET PRESET NO :001 PRESET ID :PRESET001------- PAN :XXX.XX TILT : XXX.XX DEFAULT SETTING SAVE EXIT D-1. PRESET - PRESET NO.
  • Page 30: Auto Scan Set

    Veilux Model # VP-58CND12X User Manual OSD MENU SETTING E. AUTO SCAN SET 66 + pre- button is working as AUTO SCAN after set- ting. AUTO SCAN SET START ANGLE XXX.X.XX.X END ANGLE XXX.X.XX.X DEFAULT SETTING DIRECTION : CW ENDLESS : OFF SPEED : 10°/S...
  • Page 31: Tour Set

    Veilux Model # VP-58CND12X User Manual OSD MENU SETTING F. TOUR SET 8 Programmable tours can be set and each tour can have up to 64 preset steps. After setting up the tours the 71~78 + preset buttons launch group tours # 1~8...
  • Page 32: Privacy Set

    Veilux Model # VP-58CND12X User Manual OSD MENU SETTING G. PRIVACY SET 4 Privacy masking zones can be set. PRIVACY SET PRIVACY NO : 01 DISPLAY : OFF ACTION : MOVE DEFAULT SETTING SAVE EXIT G-1. PRIVACY SET - PRIVACY NO.
  • Page 33: Pattern Set

    Veilux Model # VP-58CND12X User Manual OSD MENU SETTING H. PATTERN SET 8 programmable patterns are available, each with a programmable title. After setting up each pattern # 1~8, 81~88+ preset buttons will recall Patterns # 1~8. PATTERN SET PATT NO : 01 PATT TITLE: PATTERN01□□□□□□□...
  • Page 34: Alarm Set

    Veilux Model # VP-58CND12X User Manual OSD MENU SETTING I. ALARM SET 4 Alarm inputs are available and each input can activate presets, group tours or patterns. ALARM SET ALARM NO : 01 ALARM INPUT : OFF DEFAULT SETTING ALARM ACT...
  • Page 35: Sector Set

    Veilux Model # VP-58CND12X User Manual OSD MENU SETTING J. SECTOR SET Up to 8 programmable sectors are available, each with a 16 character title. This feature allows the various areas of the domes 360û rotation to be given logical titles.
  • Page 36: Dip Switch Setting

    Veilux Model # VP-58CND12X User Manual DIP SWITCH SETTING A. FACTORY DEFAULT SETTING The dome cameras RS 485 address is set using switches 1-6 of DIP SW1, refer to the table below... Open the camera case to set ID using DIP SW1.
  • Page 37: Protocol Setting

    Veilux Model # VP-58CND12X User Manual DIP SWITCH SETTING C. PROTOCOL SETTING dip switches are used for Protocol Setting. Factory Default: Pelco-D or Pelco-P (Auto detection) DIP SW1- 7 DIP SW1- 8 Pelco-D or Pelco-P VICON SAMSUNG D. BAUD RATE SETTING The 9 Dip Switch is used for BAUD RATE setting.
  • Page 38: Trouble Shooting

    Veilux Model # VP-58CND12X User Manual TROUBLE SHOTING If you have trouble setting up or operating the camera, refer to the following. PROBLEM SOLUTION Check if the power supply is DC12V. Check if RS-485 communication cable is connected correctly. No operation Check camera ID setting.
  • Page 39: Specification

    Veilux Model # VP-58CND12X User Manual SPECIFICATIONS MODEL 12X Mini Speed Dome Camera Pan Rotation Angle 360 Endless Pan Speed Manual Preset Max 150 /sec Max 200 /sec PAN /TILT Tilt Rotation Angle 0 ~ 90 Tilt Speed Manual Preset...
  • Page 40: Dimension

    Veilux Model # VP-58CND12X User Manual UNITS : mm Website: www.Veilux.net Phone # 1-800-510-6528...