5 - POSITIONING
REQUIREMENTS FOR INSTALLATION OF THE PLANT - POSITIONING
The most important thing to do before installation of the boiler is to set aside a suitable area that meets the minimum requirements for
installation.
•
the minimum clearance in front of the product to allow suitable access for cleaning, maintenance, etc. must be 400 mm;
•
the minimum permissible distance between the back of the product and a wall must be 10 mm;
the minimum distance between the top of the product and the ceiling must be 600 mm to ensure easy access to the heat exchanger
•
for the purpose of cleaning and maintenance (e.g. for removing ash);
the minimum clearance between the product and the wall (side) must be 300 mm.
•
MIN.
300
MIN.
300
Technical Dept. - All rights reserved - Reproduction is prohibited
COMPACT SLIM 15 BOILER MINIMUM REQUIREMENTS