5 - POSITIONING

REQUIREMENTS FOR INSTALLATION OF THE PLANT - POSITIONING
The most important thing to do before installation of the LOGIKA boiler is to set aside a suitable area that meets the minimum requirements
for installation.
the minimum clearance in front of the product for the purpose of cleaning, maintenance, etc. must be 1000 mm;
the minimum permissible distance between the back of the product and a wall must be 400 mm;
the minimum distance between the top of the product and the ceiling must be 600 mm to ensure easy access to the heat exchanger
for the purpose of cleaning and maintenance (e.g. for removing ash);
the minimum clearance between the product and the wall (side) must be 300 mm.
300
MINIMUM REQUIREMENTS FOR LOGIKA BOILER AND MANUAL TANK
26
26
815
MIN.300
815
300
MINIMUM REQUIREMENTS FOR LOGIKA BOILER AND REFILL TANK
MIN.300