RED COMPACT SLIM 15 Installation Manual page 55

Table of Contents

Advertisement

10 - MENU ITEMS AND FUNCTION
n - Maximum power
Allows you to set the maximum power limit of the flames which the boiler can use to reach the set target temperature.
Modify the power as follows:
Press the "menu" key.
Use the arrow keys to scroll through and select "Settings"
Press "menu" to confirm.
Scroll with the arrows and select ''Maximum power'' .
Press "menu" to confirm.
Change the power from 01 to 05 using the + - keys.
Press ''menu'' to confirm and ''esc'' to exit.
o - Components test
This can be done only when the boiler is off and allows you to select the components to be tested:
Spark plug: it is turned on for a fixed test period during which the panel displays the countdown in seconds.
Feed screw: it is powered for a fixed test period during which the panel displays the countdown in seconds.
Aspirator: it is activated at 2500 rpm for a fixed test period during which the panel displays the countdown in seconds.
Exchanger: enables you to conduct the test in V5 for a fixed test period during which the panel displays the countdown in seconds.
Pump: it is activated for a fixed period of 10 seconds during which the panel displays the countdown.
3-way valve: the 3-way valve is activated for a fixed test period of 1 minute during which the panel displays the countdown in
seconds.
Enable the "Component test" function (only with boiler off) as follows:
Press key 3 ''menu'' .
Use the arrow keys to scroll through and select "Settings"
Press 3 "menu" to confirm.
Use the arrow keys to scroll through and select ''Component test''
Press 3 "menu" to confirm.
Use the + - keys to select the test to be carried out.
Press ''menu'' to confirm and ''esc'' to exit.
p - Chimney sweep Function
This function can only be activated when the boiler is on and power is supplied, and it forces operation of the boiler at the parameters
P5, with the ventilator (if present) in V5. Any corrections to the loading/smoke ventilation percentage must be read. This state lasts 20
minutes, the countdown is displayed on the panel. During this interval, the system ignores any thermostat/puffer/room set point/ set
point H
0 values, only the safety shut-down at 85°C remains active. At any time, the technician may interrupt this phase by pressing the
2
on/off switch quickly.
Enable the "Chimney sweeper" function as follows:
Press the ''menu'' key.
Use the arrow keys to scroll through and select "Settings"
Press "menu" to confirm.
Use the arrow keys to scroll through and select ''Chimney sweeper function''
Press "menu" to confirm.
Use the + - keys to select "On" (Off by default)
Press ''menu'' to confirm and ''esc'' to exit.
Technical Dept. - All rights reserved - Reproduction is prohibited
53

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents