Copy of Safety Label
Listed: VENTED GAS FIREPLACE HEATER /
FOYER AU GAZ À ÉVACUATION
Certified to/Certifié : CSA 2.17-2017
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE
Refer to Intertek's Directory of Building Products for detailed information.
4001172
Pour plus de détails, se reporter au Répertoire des produits de construction de Intertek.
FACTORY EQUIPPED FOR NATURAL GAS
Minimum supply pressure
Manifold pressure High
Manifold pressure Low
Orifice Size
Maximum Input
Minimum Input
Altitude
FACTORY EQUIPPED FOR PROPANE GAS
Minimum supply pressure
Manifold pressure High
Manifold pressure Low
Orifice Size
Maximum Input
Minimum Input
Altitude
Minimum Clearances to Combustibles/Dégagements minimaux
par rapport aux matériaux combustibles
Minimum ceiling height from top of unit:36"/914mm
Hteur min. de plafond depuis le dessus de l'appareil : 36"/914mm
A 6-1/2"/165mm
B 6"/152mm
Minimum clearance of Vent Terminal to Outside Corner & Inside Corner:
with AstroCap 6"/150mm with Dura-Vent Cap 12"/300mm
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas
and Propane Installation Code, CSA B149.1.
This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured
Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the United States, or when such a standard is not applicable, ANSI/NCS-
BCS A225.1/NFPA 501A, Manufactured Home Installations Standard or ANSI A119.2 ou NFPA 501C Standard for Recreational Vehicles
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located,
manufactured (mobile) home where not prohibited by local codes. See owner's manual for details.
Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation ANSI Z223.1, Na-
tional Fuel Gas Code ou CSA-B149.1 en vigueur.
Installer l'appareil selon la norme CAN/CSA-Z240, Série MM, Maison mobiles ou CAN/CSA-Z240 VC, Véhicules de camping, ou la norme 24
CFR Part 3280, Manufactured Home Construction and Safety Standard. Si ces normes ne sont pas pertinentes, se référer à la norme ANSI/
NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard, ou ANSI A119.2 ou NFPA 501C Standard for Recreational Vehicles.
Cet appareil doit être utilisé uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison
préfabriquée ou mobile (É.-U. seulement) installée à demeure si les règlements locaux le permettent. Voir le guide d'utilisation pour plus de
renseignements. Cet appareil ne peut pas être utilisé avec d'autres gaz sauf si une trousse de conversion certifiée est fournie.
This vented gas fireplace heater is not for use with air filters.
For use with Fan Kit # 743-917
For use with glass doors certified with the appliance only.
ELECTRICAL SUPPLY/ALIMENTATION ÉLECTRIQUE : 115V_60HZ less than/moins de 2 AMP
For Use Only with Barrier (Part # 743-100) Follow installation instructions.
Utiliser uniquement avec un écran de sécurité (pièce n°743-100) Suivre les consignes d'installation.
NOT FOR USE WITH SOLID FUELS. / NE PAS UTILISER AVEC UN COMBUSTIBLE SOLIDE
FPI Fireplace Products International Ltd. Delta, BC, Canada
CANADIAN ENERGY
PERFORMANCE
ÉNERGÉTIQUE
EP5011169
Part #: 920-088
Decal Location
Colour: Everything black on grey except for items indicated in red.
Size:
Printed at 100% (H 9.19" x w 6.25")
Material: 2 ml silver matt polyester (DPM SMS)
Mar 14/19: Created Decal - New Material (double sized)
*Printer: Start number sequence @515000001
|
6
Hampton
H35E-11 Direct Vent Freestanding Gas Stove
®
DUPLICATE SERIAL NO.
ANSI Z21.88-2017
CSA 2.33-2017
Model:H35E-NG11
5"
WC/C.E. (1.25 kPa)
3.5" WC/C.E. (0.87 kPa)
1.6" WC/C.E. (0.40 kPa)
#37 DMS
30,000 Btu/h (8.78 Kw/h)
21,500 Btu/h (6.30 Kw/h)
0-4500 ft/pi (0-1372m)
Model:H35E-LP11
11"
WC/C.E. (2.74 kPa)
10" WC/C.E.
(2.49 kPa)
6.4" WC/C.E. (1.59 kPa)
#52 DMS
29,500 Btu/h (8.64 Kw/h)
24,000 Btu/h (7.03 Kw/h)
0-4500 ft/pi (0-1372m)
C 2" / 50mm
E 2"/50mm
Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.
À utiliser avec la trousse du ventilateur n
À utiliser uniquement avec les portes vitrées certifiées avec l'appareil
CSA P.4.1 Fireplace Efficiency (FE) /Efficacité énergétique des foyers (EEF) CSA P.4.1
VERIFIED
Natural Gas / Gaz naturel 70.86%
Propane Gas / Gaz propane 71.97%
RENDEMENT
VÉRIFIÉ
DO NOT REMOVE THIS LABEL / NE
PAS ENLEVER CETTE ÉTIQUETTE
Serial No./ No de série
APPAREIL FONCTIONNANT AU GAZ NATUREL
Pression d'alimentation minimale
Pression manifold élevée
Pression manifold basse
Taille de l'orifice
Débit calorifique maximal
Débit calorifique minimal
Altitude
APPAREIL FONCTIONNANT AU GAZ PROPANE
Pression d'alimentation minimale
Pression manifold élevée
Pression manifold basse
Taille de l'orifice
Débit calorifique maximal
Débit calorifique minimal
Altitude
Left Side Wall
Left Side Wall
A
A
C
B
Vertical
Horizontal
Pipe
Pipe
A
A
Right Side Wall
Right Side Wall
743-917
o
Made in Canada/Fabriqué au Canada
515
515
For the State of Massachusetts,
installation and repair must be
done by a plumber or gas fitter
licensed in the Commonwealth of
Massachusetts.
For the State of Massachusetts,
flexible connectors shall not ex-
ceed 36 inches in length.
For the State of Massachusetts,
the appliances individual manual
shut-off must be a t-handle type
valve.
The State of Massachusetts
requires the installation of a carbon
monoxide alarm in accordance
with NFPA 720 and a CO alarm
with battery back up in the same
E
room where the gas appliance is
installed.
E
920-088
Fold down access door, and then remove two screws
as shown below
With the panel removed, the gas valve will be visible.
The rating plate will be attached to a black chain
located under the IFC.
DO NOT REMOVE THE DECAL FROM THE UNIT.