Dimmer Profiles; Program Upload; Reset - Chauvet COLORado 1 Solo User Manual

Hide thumbs Also See for COLORado 1 Solo:
Table of Contents

Advertisement

Dimmer Profiles

Program Upload

Reset

COLORado 1 Solo User Manual Rev. 1
This setting determines how fast the output of the COLORado 1 Solo changes when you modify
the values of the red, green, blue, white, and dimmer faders. This setting provides four different
options to simulate the dimming curve of an incandescent lighting product.
1. Go to the SETTING main level.
2. Enter the master access passcode as described in Passcode.
3. Select DIMMER.
4. Select a dimmer curve (OFF, DIM1, DIM2, DIM3, or DIM4).
OFF:
The output is proportional (linear) to the dimmer and RGBW channel values.
DIM1–4:
The output follows the dimmer and RGBW channel values based on the
corresponding dimmer curve, DIM1 being the fastest and DIM4 the slowest.
For optimum control of the 16-bit dimming channels in the TR16 and STD.Y personalities,
be sure that both dimming curves in SETTING > DIMMER are set to OFF.
When the control panel lock is active, the product will prompt you to enter the passcode
after 30 seconds of control panel inactivity or after turning on the product. See
Passcode.
This option allows you to copy the custom programs of one COLORado 1 Solo onto other
COLORado 1 Solo by using the Master/Slave mode.
1. Configure and connect the products in a Master/Slave arrangement, where the master has
the custom programs you want to transfer to the slaves.
2. From the master, go to the SETTING main level.
3. Enter the master access passcode as shown in Passcode.
4. Select UPLOAD.
5. Enter the master access passcode as shown in Passcode.
6. When SEND shows, press <ENTER> to start the upload.
7. Wait for the upload process to finish (the display will show END before continuing or turning
the products off.
The master and slaves will provide the status of the process by lighting up as follows:
·
Yellow indicates that the upload process is running.
·
Green indicates that the upload process completed successfully.
·
Red indicates that the upload process failed due to an error. Recheck all cable
connections and restart the process. If the issue persists, contact Chauvet Technical
Support.
DO NOT upload the data from a COLORado 1 Solo to a different product. The other
product may become inoperative.
This setting allows you to reset the COLORado 1 Solo to the default values, including the
custom programs.
1. Go to the SETTING main level.
2. Enter the master access passcode as described in Passcode.
3. Select RESET.
4. Enter the master access passcode as described in Passcode.
5. Wait for the reset process to finish.
Operation
-13-

Advertisement

Table of Contents
loading

Table of Contents