This point-of-use system allows for simple installation and operation due to its high output
lamp and compact reactor. The reactor is an axial flow design with superior hydraulics, com-
pact design and 1" NPT connections. The controller is a simple plug in device connecting to
the lamp with a safety cap.
Water Quality Guidelines
Iron
< 0.3 ppm (0.3 mg/L)
Hardness
< 7 gpg (120 mg/L)
Turbidity
< 1 NTU
Manganese
< 0.05 ppm (0.05 mg/L)
Tannins
< 0.1 ppm (0.1 mg/L)
UV Transmittance > 85%
The UV light system uses ultraviolet let to kill bacteria and other organics in the water source.
The light from the UV bulb passes through the water and destroys the organic contaminants.
The UV bulb is utilizes a quartz sleeve on the outer portion to isolate the water from the UV
bulb element.
WARNING!
If this quartz sleeve becomes coated or stained it will reduce the light that can pass
through the water in the chamber, thus inhibiting the bacteria removal by the UV light.
It is crucial that the iron, manganese and any tannins in the water are removed prior to
the UV to ensure the light is penetrating the quartz sleeve and its' full intensity.